Rated supply voltage: AC 3*220V
Max load current: 100A
Current protection: 1-100A adjustable
Operation voltage range: AC140V-300V
Rated frequency:50/60Hz
Hysteresis:Over voltage and asymmetry:5V, Under voltage: 3V
Asymmetry trip delay: 10s
Voltage measurement accuracy: ≤1%
(over the whole range)
Rated insulation voltage: 450V
Output contact: 1NO
Electrical life: 100000
Mechanical life: 100000
Protection degree: IP20
Pollution degree: 3
Altitude: ≤2000m
Humidity:
PHASE SETECTOR OPERATE RANGE
-
Technical parameter | Setting range | Setto Step | Function description | |
Power-on delay time | 15-500s | 10s | 1s | After external power cut, the time needed for power-on when power recovery. |
Over-voltage protection value | 230V-300V | 270V | 1V | When the voltage of one phase is over the set value, the protector will cut off this phase and switch to the next phase according to the sequence set in Pr1 When all three phases' cultaffal iner the set value, the protector will |
Over-voltage recovery value | 225V-295V | 265V | When the voltage is 5V or more than 5V lower than the over-voltage protection value, the protector will automatically reset. This parameter automatically changes with the ches no rever to te se protection value and | |
Under-voltage protection value | 140V-210V | 170V | 1V | When the voltage of one phase is under the set value, the protector will cut off this phase andswitch to the next phase according to the sequence set in Pr1.When all three phases' voltageis under the set value, the protector will cut off all lines |
Undeery vage | 145V-215V | 175V | When the voltage is 5V or more than 5V higher than the under-voltage protection value, theprotector will automatically reset. This parameter automatically changes with the change ofover-voltage protection value and does not need to be set. | |
Over-current protection value | 3A-63A-OFF 3A-100A-OFF | 40A 60A | 1A | When the current is higher than the set value, the protector will cut off the line. When setting OFF, the protector will turn off over-current protection function. |
Times of continuous over current protection | OFF-1-20 | OFF | 1 | When The times of continuous over-current protection exceeds the set value, the protector willcut off the line, then it needs to be opened manually. |
Phase sequence switching detection time | OFF-1S-500S | 10S | 1S | The time required to detect whether the voltage of the priority phase is stable before disconnect OFF means that there is no need to wait for detection and switch directly to the priority phase. |
Phase sequence recovery switching settings | ON | ON-OFF | ON means that when the priority phase returns to normal, it will switch to the priority phase.OFF means that even if the priority phase returns to normal, the protector will not switch to thatphase. | |
Phase sequence switching recovery time | OFF-1S-500S | 10S | 15 | Time required to switch to priority phase. |
over-current protection action time | 0.15-30s | 1.05 | 0.15 | When over current, the time needed for protection action. |
Voltage calibration | -9.5%-9.5% | 0.5 | Correct the voltage error. | |
Current calibration | -9.5%-9.5% | 0.5 | Correct the voltage error. | |
Input phase priority selection | АВС-АСВ- BAC-BCA- САВ-СВА | - ABC | Set the input priority of each phase.A:L1,B:L2,C:L3 |