HomeMusical InstrumentsElectronic Music, DJ & KaraokeElectronic MusicSound ModulesXY-CD60 XY-CD60L Lead-Acid Lithium Battery Charger Control Module Automatic Charging Overcharge Protection Board Switch
product_image_name-Generic-XY-CD60 XY-CD60L Lead-Acid Lithium Battery Charger Control Module Automatic Charging Overcharge Protection Board Switch-1

Share this product

Shipped from abroad

XY-CD60 XY-CD60L Lead-Acid Lithium Battery Charger Control Module Automatic Charging Overcharge Protection Board Switch

GH₵ 348.17
GH₵ 552.5037%

In stock

Order above GHC 150 on Jumia Express items & get free delivery | regular delivery from GH₵ 46.37 to Tema
0 out of 5
(No ratings available)
Variation available

Promotions

Delivery & Returns

Shipped from abroad 

Choose your location

Pickup Station

Delivery Fees GH₵ 46.37
Ready for pickup between 08 April and 17 April if you place your order within the next 14hrs 19mins

Door Delivery

Delivery Fees GH₵ 66.37
Ready for delivery between 08 April and 17 April if you place your order within the next 14hrs 19mins

Return Policy

Free return within 15 days for all eligible items.Details

Seller Information

dsfsdf

98%Seller Score

1 Followers

Follow

Seller Performance

Quality Score: Excellent

Product details

Package : TQFPis_customized : YesModel Number : XY-CD60Operating Temperature : NORMALDissipation Power : lowSupply Voltage : -Application : ComputerCondition : NewType : Drive ICBrand Name : Your Cee : Mainland China
Made of high quality material, sturdy, durable and practical to use.Great for fixing overload and low voltage, protects the battery from undervoltage, protects the battery from overcharging, and protects the load control, pro battery life.When the battery voltage is insufficient, disconnect the load and connect the charger. When the battery voltage is too high, disconnect the charger and connect the load.Adjustable and LCD screen, show you the clearly, easy to use.With a control voltage 6-60V, it is suitable for batteries, lithium batteries, etc..Specification:Material: PlasticModel: XY-CD60Size: app.79 x 43 x 38mm/3.11 x 1.69 x 1.50inControl voltage: 6-60VModes: Charging Mode; Discharging ModeColor: shownCharging mode IN:By setting the upper limit voltage UP and the lower limit voltage dn; when the battery voltage is less than or equal to the lower limit voltage dn, the relay turns on and the charger starts charging the battery; when the battery voltage is more than or equal to the upper limit voltage UP, the relay disconnects to complete an automatic charging; when the relay turns on, IN flickers, indicating that it is charging.Discharging mode OUT:By setting the upper limit voltage UP and the lower limit voltage dn; when the battery voltage is greater than or equal to the upper limit voltage UP, the relay turns on and starts discharging; when the battery voltage is less than or equal to the lower limit voltage dn, the relay turns off and completes an automatic discharging function; when the relay turns on, the OUT flickers, indicating that it is discharging.Note:This product is a simple voltage controller. It can turn on and off the output by relay. It only plays the role of switching, and can not change the voltage.Functional instruction:1. Calculation of Voltage Percentage: Battery Voltage/(Upper Voltage-Lower Voltage)2. Key function:UP: Short press display % and time, press 5 seconds to switch mode; charging mode: IN, discharge mode: OUT.SET: Short press to check the currently set; press to enter the parameter setting interface, set UP: voltage upper limit, dn: voltagelower limit, OP: turn-on time, dOP: delay turn-on time (0-999 seconds), FOP: forced turn-on time (0-10 seconds) in discharge mode.DOWN: Turn off/on electric relay enable (emergency stop function) turn off, LCD display OFF, relay disconnect: press to set the status of LCDbacklight, L-P: OFF backlight constant brightness, ON: Backlight automatically extinguishes after 5-10 minutes; after extinguishing, pressany keys to wake up.3. Parameter Settingsa. Enter the parameter setting interface by pressing the SET;b. After entering the parameter setting interface, switch the setting by short pressing SET;c. After choosing , it can be set by UP/DOWN key, supporting short press or press.d. If you want to set other , repeat steps b and c;e. After all are set, press SET to exit and save;3.1 Charging/Discharging Time Control Function1) When the time parameter OP is non-zero, start charging/discharging time control.2) When the relay turns on a charge/discharge, the countdown begins; when it is completed, the relay is automatically disconnected to complete acharge/discharge process; if the time is completed, under the charging mode, the detection voltage is less than the lower limit voltage dn or inthe discharge mode, the detection voltage is larger than the upper limit voltage UP, and the charging time control function is automatically turnedoff and flashes. Indicate H: ER reminds users that time parameter setting is unreasonable; press any key to stop flickering;3) When the charging/discharging time control is not turned on, the product will record a complete time. When entering the time display interface,flashing shows the charging time, then exiting the time display interface or clearing the next time the charging is turned on (relay is turned on).3.2 Automatic parameter detection:When the are set and exit, if the lower voltage limit DN is larger than the upper voltage up, the system will flicker to display "ERR" as a reminder.3.3 Delayed turn-on function (0-999 seconds):Completion of a charge/discharge, the interval between re-opening;3.4 Discharge Conduction Forced Start Time (0-10S):After satisfying the relay conduction condition, the relay is forced to turn on (0-10S) to detect the battery voltage again. This function is mainly aimed at discharging function. Some test loads will pull down the lower limit voltage instantaneously at the moment of conduction, which will lead to the disconnection of the relay and the failure of normal discharge process.Analysis of Common Faults:Question 1: How many V levels are suitable for use? How many V voltage does this module fit?Answer 1: This model is suitable for use in the range of minimum 6V, maximum 60V voltage and maximum expenditure level 48V, because 48V battery is full of electricity at about 60V, and then burns at a higher level. If your battery is higher than 48V, please choose another one.Q2: The relay clicks after power-on! Does the light flicker?A2: This is because your charging current is too large or the battery capacity is too small. Once the battery is powered up, it immediately reaches the upper voltage limit. The relay is disconnected. After disconnection, the voltage quickly drops to the lower voltage limit and starts charging again. At this time, you need to reduce the charging current. Usually, the charging current is 10% of the battery capacity. From 1 to 1.5, the charging current of 20AH batteries is generally about 2-3A. Note that high current charging can cause battery heating, accelerated aging, bulging and even explosion!Q3: What control method? Can it be recharged automatically? Can you fill it while you use it? Can we limit the current?A3: This is voltage control, such as setting the lower limit of voltage 12.0V, the upper limit of voltage 14.5V, when the voltage is charged to 14.5V, the power is cut off, the voltage is lowered to 12.0V and the relay is closed to start charging; while charging, the voltage control mode can only switch on and off, not limit the current, the charging current depends entirely on your charger!Q4: Can I charge a 24V battery with 12V input, or can I charge a 12V battery with 48V input?A4: This is a simple voltage controller. It only plays a switching role. It can't change the voltage to charge the battery. So what kind of charger should you prepare to charge the battery? Necessary!Note:Please allow 0-1cm error due to manual measurement. pls make sure you do not mind before you bid.Due to the difference between different monitors, the picture may not reflect the actual color of the item.
image


image


image


image


image


image


Specifications

Key Features

Package : TQFPis_customized : YesModel Number : XY-CD60Operating Temperature : NORMALDissipation Power : lowSupply Voltage : -Application : ComputerCondition : NewType : Drive ICBrand Name : Your Cee : Mainland China
Made of high quality material, sturdy, durable and practical to use.Great for fixing overload and low voltage, protects the battery from undervoltage, protects the battery from overcharging, and protects the load control, pro battery life.When the battery voltage is insufficient, disconnect the load and connect the charger. When the battery voltage is too high, disconnect the charger and connect the load.Adjustable and LCD screen, show you the clearly, easy to use.With a control voltage 6-60V, it is suitable for batteries, lithium batteries, etc..Specification:Material: PlasticModel: XY-CD60Size: app.79 x 43 x 38mm/3.11 x 1.69 x 1.50inControl voltage: 6-60VModes: Charging Mode; Discharging ModeColor: shownCharging mode IN:By setting the upper limit voltage UP and the lower limit voltage dn; when the battery voltage is less than or equal to the lower limit voltage dn, the relay turns on and the charger starts charging the battery; when the battery voltage is more than or equal to the upper limit voltage UP, the relay disconnects to complete an automatic charging; when the relay turns on, IN flickers, indicating that it is charging.Discharging mode OUT:By setting the upper limit voltage UP and the lower limit voltage dn; when the battery voltage is greater than or equal to the upper limit voltage UP, the relay turns on and starts discharging; when the battery voltage is less than or equal to the lower limit voltage dn, the relay turns off and completes an automatic discharging function; when the relay turns on, the OUT flickers, indicating that it is discharging.Note:This product is a simple voltage controller. It can turn on and off the output by relay. It only plays the role of switching, and can not change the voltage.Functional instruction:1. Calculation of Voltage Percentage: Battery Voltage/(Upper Voltage-Lower Voltage)2. Key function:UP: Short press display % and time, press 5 seconds to switch mode; charging mode: IN, discharge mode: OUT.SET: Short press to check the currently set; press to enter the parameter setting interface, set UP: voltage upper limit, dn: voltagelower limit, OP: turn-on time, dOP: delay turn-on time (0-999 seconds), FOP: forced turn-on time (0-10 seconds) in discharge mode.DOWN: Turn off/on electric relay enable (emergency stop function) turn off, LCD display OFF, relay disconnect: press to set the status of LCDbacklight, L-P: OFF backlight constant brightness, ON: Backlight automatically extinguishes after 5-10 minutes; after extinguishing, pressany keys to wake up.3. Parameter Settingsa. Enter the parameter setting interface by pressing the SET;b. After entering the parameter setting interface, switch the setting by short pressing SET;c. After choosing , it can be set by UP/DOWN key, supporting short press or press.d. If you want to set other , repeat steps b and c;e. After all are set, press SET to exit and save;3.1 Charging/Discharging Time Control Function1) When the time parameter OP is non-zero, start charging/discharging time control.2) When the relay turns on a charge/discharge, the countdown begins; when it is completed, the relay is automatically disconnected to complete acharge/discharge process; if the time is completed, under the charging mode, the detection voltage is less than the lower limit voltage dn or inthe discharge mode, the detection voltage is larger than the upper limit voltage UP, and the charging time control function is automatically turnedoff and flashes. Indicate H: ER reminds users that time parameter setting is unreasonable; press any key to stop flickering;3) When the charging/discharging time control is not turned on, the product will record a complete time. When entering the time display interface,flashing shows the charging time, then exiting the time display interface or clearing the next time the charging is turned on (relay is turned on).3.2 Automatic parameter detection:When the are set and exit, if the lower voltage limit DN is larger than the upper voltage up, the system will flicker to display "ERR" as a reminder.3.3 Delayed turn-on function (0-999 seconds):Completion of a charge/discharge, the interval between re-opening;3.4 Discharge Conduction Forced Start Time (0-10S):After satisfying the relay conduction condition, the relay is forced to turn on (0-10S) to detect the battery voltage again. This function is mainly aimed at discharging function. Some test loads will pull down the lower limit voltage instantaneously at the moment of conduction, which will lead to the disconnection of the relay and the failure of normal discharge process.Analysis of Common Faults:Question 1: How many V levels are suitable for use? How many V voltage does this module fit?Answer 1: This model is suitable for use in the range of minimum 6V, maximum 60V voltage and maximum expenditure level 48V, because 48V battery is full of electricity at about 60V, and then burns at a higher level. If your battery is higher than 48V, please choose another one.Q2: The relay clicks after power-on! Does the light flicker?A2: This is because your charging current is too large or the battery capacity is too small. Once the battery is powered up, it immediately reaches the upper voltage limit. The relay is disconnected. After disconnection, the voltage quickly drops to the lower voltage limit and starts charging again. At this time, you need to reduce the charging current. Usually, the charging current is 10% of the battery capacity. From 1 to 1.5, the charging current of 20AH batteries is generally about 2-3A. Note that high current charging can cause battery heating, accelerated aging, bulging and even explosion!Q3: What control method? Can it be recharged automatically? Can you fill it while you use it? Can we limit the current?A3: This is voltage control, such as setting the lower limit of voltage 12.0V, the upper limit of voltage 14.5V, when the voltage is charged to 14.5V, the power is cut off, the voltage is lowered to 12.0V and the relay is closed to start charging; while charging, the voltage control mode can only switch on and off, not limit the current, the charging current depends entirely on your charger!Q4: Can I charge a 24V battery with 12V input, or can I charge a 12V battery with 48V input?A4: This is a simple voltage controller. It only plays a switching role. It can't change the voltage to charge the battery. So what kind of charger should you prepare to charge the battery? Necessary!Note:Please allow 0-1cm error due to manual measurement. pls make sure you do not mind before you bid.Due to the difference between different monitors, the picture may not reflect the actual color of the item.

What’s in the box

1x packages

Specifications

  • SKU: GE779MI4S1UFINAFAMZ
  • Model: sm-yymk-10-16-165
  • Production Country: China
  • Size (L x W x H cm): 20x10x20
  • Weight (kg): 0.4
  • Color: XY-CD60
  • Main Material: other

Verified Customer Feedback

This product has no ratings yet.

XY-CD60 XY-CD60L Lead-Acid Lithium Battery Charger Control Module Automatic Charging Overcharge Protection Board Switch

XY-CD60 XY-CD60L Lead-Acid Lithium Battery Charger Control Module Automatic Charging Overcharge Protection Board Switch

GH₵ 348.17
GH₵ 552.5037%
Questions about this product?

Recently Viewed

See All