This website uses cookies
This website uses cookies. For further information on how we use cookies you can read our Privacy and Cookie notice
This website uses cookies. For further information on how we use cookies you can read our Privacy and Cookie notice
In stock
Shipped from abroad
Free return within 15 days for all eligible items.Details
MOMONIYA
92%Seller Score
14 Followers
Shipping speed: Good
Quality Score: Excellent
Customer Rating: Excellent
SHT2000 Temperature and Humidity Controller Operating Instructions Product Name: Temperature and Humidity Controller Product Model: SHT2000 Supply voltage: AC 110~230V Power supply frequency: 50/60Hz Temperature range: -20~60°C Humidity range: 0%~100%RH Temperature measurement accuracy: 0.3 °C Humidity measurement accuracy: 3% Output Control: Relay Output Output Power: MAX 10A Setting method: Start value stop value (the program automatically determines the working mode is cooling/dehumidifying mode) Heating/cooling mode setting: Setting mode: setting (starting temperature): Pre and hold the ▲ on to start the temperature flashing. Use ▲▼ key to set the starting temperature value. Setting (stop temperature): Pre and hold the ▼ on to stop the temperature flashing. Use ▲▼ to set the stop temperature value. Heating use case: control the water heater, heat to 65 ° C to stop, the temperature drops back to 50 ° C and start heating again Step 1: heating mode, starting temperature stop temperature Step 2: Pre and hold the ▲ on to start the temperature flashing. Use ▲▼ to set the starting temperature to 30 °C. Step 3: Pre and hold the ▼ on to stop the temperature flashing. Use ▲▼ to set the stop temperature to 26°C. The setting is completed! Humidification/Dehumidification Mode Settings: Setting (start humidity): Pre and hold △ key to start the humidity value flashing. Set the humidity value by △ ▽ key. Set [Stop Humidity]: Pre and hold △ key to stop the humidity value flashing, and set the humidity to stop by △ ▽ key value. Humidification example: fresh supermarket humidification, control humidifier 50% RH began to humidify, humidified to 80% RH to stop humidification. Setup steps: Step 1: Pre and hold the △ on for 3 seconds to start the humidity value flashing, and set the starting humidity value to 50% RH. Step 2: long pre the ▽ on for 3 seconds to stop the humidity value flashing, set the value to 80% RH, the setting is completed, the on does not operate for 5 seconds, and automatically returns to the normal display state. Dehumidification example: workshop control exhaust dehumidification system, humidity 70% RH starts dehumidification, humidity 40% RH stops dehumidification Setup steps: Step 1: Pre and hold the △ on for 3 seconds to start the humidity value flashing, and set the starting humidity value to 40% RH. Step 2: Pre and hold the ▽ on for 3 seconds to stop the humidity value flashing, set the value to 70% RH, the setting is completed, the on does not operate for 5 seconds, and automatically returns to the normal display state. Package included: 1Pcs x AC 110V-230V 10A SHT2000 LED Digital Humidity Temperature Controller Thermostat Humidistat Therometer Hygrometer Water Heater
STC-3028
Feature: Be able to control temperature and humidity at the same time. Be able to connect with humidifier and dehumidifier equment at the same time. Be able to connect with refrigeration/ heating and humidifier/dehumidifier equment at the same time. Heating/Cooling function could be set separately for refrigeration and heating to protect temperature controller from violent change. Same as humidity Control. Supporting Temp and Humidity Calibration [Dual Display Window] Be able to display measured temperature/humidity and set temp/humidity at the same time Specification: Model: STC-3028 Input voltage: AC110~220V± 10%, DC24V, DC12V Measuring temperature range: -20°~+80° Measuring humidity range: 00%RH~+100%RH Accuracy: ±1°, 0.1%RH Relay output contact capacity: 10A/240VAC Shell material: PC + ABS fireproof r length: 1m Set startup temperature(humidity): Pre the "up" on once to display the starting temperature(humidity). Long pre the "up" on for about 3 seconds,The required temperature(humidity) can be set by the up and down keys Set stop temperature(humidity): Pre the "down"on once to display the stop temperature(humidity). Long pre the on for about 3 seconds and the stop temperature(humidity) number flashes. The required temperature(humidity) can be set by the up and down keys Temperature/humidity correction: Pre "up" and "down" on at the same time. Package included: 1 X Temperature Humidity Controller STC-3029 Features: Reliable performance and high work efficiency Priority material, precise sensing A variety of voltages are available for a wide range of applications Fast response and good interchangeability Widely used in water-saving irrigation, greenhouses, flowers and vegetables, plant cultivation and other fields Product Name: Soil Controller Model: STC-3029 Supply voltage: DC12V/DC24V/AC110-220V optional Relay: 10A Output power: 120W/240W/1500W Humidity range: 0-100%RH Control accuracy: 0.1%RH r length: default 1 meter Product size: 75*34.5*85mm Installation size: 71*29mm Shping list: Humidity Controller X1About shping
This product has no ratings yet.
Subscribe to our newsletter
and be the first one to know about our amazing deals!