Permanent data storage, building doents for searching, data could be read and printed by PC data management software. Directly connect with computer for data exchange, easy operation: When connected to computer, the software will automatically read data, and form reports.
Specifications: Temperature measuring range: -30℃~+60℃ (Internal sensor)for optional external sensor: -40℃~+85 ℃ (optional external sensor)
Temperature Accuracy: +/-0.5 (-20℃/+40℃)
+/-1.0(other range)
Temperature Resolution: 0.1 ℃
Data Storage capacity: 16000 points readings
Record interval: 10s~24hour adjustable
Stop Mode: on, software or stop when full
Startup Mode: on
Validation Certification: Hardcopy
Certifications: EN12830, CE, RoHS
Connection Interface: Mini USB
Alam Configuration: Optional, only 2 points
Software: ElitechLog Win or Mac(latest version)
Report Generation:PDF&Excel report by Elitech software
Power supply: 1years^1/CR2450 battery cell(do not included)
Battery life: in normal temperature, if the record interval sets as 15 minutes, it could be used above one year.
Item Size: approx. 84 (L) x 44 (W) x 20 (H) mm (3.3 x 1.73 x 0.79 inch)
Item Net Weight: 34 g
Package:1 x Data Logger
1 x External Sensor
1 x USB Cable
1 x Instruction Manual
Note:1. Please store the logger in indoor environment.
2. Do not use the logger in corrosive liquid or exceive heat environment.
3. If this is the first time you use the logger, it is suggested to connect the logger to a computer to sync the time.
4.Please dispose or handle the waste logger properly by local legislation.
Selection 2: RC-4HC
Specifications:
Temperature measuring range: -30℃~+60℃ (Internal sensor)for optional external sensor: -40℃~+85 ℃ (optional external sensor)
Temperature Accuracy: +/-0.5 (-20℃/+40℃)
+/-1.0(other range)
±3%RH(25℃,20%RH to 90%RH)
±5%RH(other range)
Temperature Resolution: 0.1 ℃,0.1%RH
Data Storage capacity: 16000 points readings
Record interval: 10s~24hour adjustable
Stop Mode: on, software or stop when full
Validation Certification: Hardcopy
Certifications: EN12830, CE, RoHS
Connection Interface: Mini USB
Alam Configuration: Optional, only 2 points
Software: ElitechLog Win or Mac(latest version)
Report Generation:PDF&Excel report by Elitech software
Power supply: 1years^1/CR2450 battery cell(do not included)
Battery life: in normal temperature, if the record interval sets as 15 minutes, it could be used above one year.
Item Size: approx. 84 (L) x 44 (W) x 20 (H) mm (3.3 x 1.73 x 0.79 inch)
Package:
1 x Data Logger
1 x External Sensor
1 x USB Cable
1 x Instruction Manual
Selection 3: RC-5
Application:
This date logger is mainly used for temperature recording during storage and transportation of foodstuff, medicine, chemicals and other products, especially widely used in all links of warehousing, logistics and cold chain, such as refrigerated containers, refrigerated trucks, refrigerated package, cold storage, laboratory, etc.
Specifications:Model:RC-5
Type: Digital Temperature Data Logger
Power supply: Built-in wide temperature CR2032 on battery or USB interface
Temperature range: -30°C ~ 70°C
Temperature measurement accuracy: -20 °C ~ 40 °C Within the temperature range, the accuracy is ± 0.5 °C; the remaining ± 1 °C
Recording capacity: 32000 sets
Record interval: 10 seconds to 24 hours can be set as needed
Resolution: 0.1 °C
Sensor: Built-in NTC thermistor
Data Interface: USB Interface
Data output: USB socket directly connected to the computer
Protection cla: 67
Product Size: 80 x 33 x 14(mm)
Use battery: CR2032 on battery(not include )
Selection 4: RC-5+
Specifications:
Model : RC-5+
Type : Digital Thermometer
Temperature measurement range: -30 ° C ~ 70 ° C ( ° C)
Temperature measurement accuracy: -30 °C ~ 40 °C temperature range, accuracy ± 0.5 (°C); other temperature, accuracy ± 1 ° C
Recording capacity: 32000 readings
Recording interval:2 minutes (standard)
Validation certificate:Hardcopy
Recording interval: 10 seconds - 24 hours can be set as needed
Resolution: 0.1 ° C
Sensor: Built-in NTC thermistor
Data interface: USB interface
Data output: USB interface directly connected to the computer
Protection level: 67
Mode: multle on/off mode
Alarm: multle temperature alarm, range alarm
Start mode: manual mode / timed start
Stop mode:on,software or stop when full
PC software: no need to install
Size : 80*25*12 (mm)
Selection 5: GPS-6
Product overview:
This data logger is mainly used to record the temperature and humidity of food,pharmaceuticals and chemicals,etc.in the storage and transportation.It is widely applicable to each link in storage and logistics of cold chain,such as refrigerated container,refrigerator truck,cooler bag,cool cabinet,medicine cabinet,cold storage,laboratory,etc.
This data logger conforms to GSP standard of new edition. It has one big LCD screen,a on,an external temperature sensor and an external humidity sensor. With two modes to save data: full record stop and cyclic record,the data logger has the functions of over limit sound-light alarm. It can also automatically shorten the record interval in case of over temperature and humidity limit. Two pieces of built-in magnets are convenient to fix the data logger onto metal material surface.
Specification:Temperature measuring range:-40℃~85℃
Temperature accuracy:±0.5℃(-20℃~40℃);±1℃(others)
Humidity range:10%~99%
Humidity accuracy;±3%RH(25C,20%~90%RH);±5%RH(others)
Resolution: temperature 0.1℃,humidity 0.1%RH
Record capacity:16000 points(MAX)
Dimension;118 (length)*61.5(width)*19(height)(mm)
Record interval:10 sec~24 hour continuously set
Data interface:USB
Power supply:single-use 3.6V lithium battery or powered via USB
Battery life:two years at room temperature with 15 minute record interval and alarm disabled
Ambient temperature:-30℃~70℃.At low temperature environment,the LCD screen displays normal record but a little slowly.It will display data normally when the ambient temperature returns to normal.
Use the data logger for the first time:1. Install the data management software for RC-61 data logger (referred to as the data management software).Insert the data logger to a computer USB port and install the setup software according to the prompt information.
2. Open the software, and the data logger will automatically upload information after connected to the computer.
3.Click the icon "set parameter"and set the parameters according to your desire. Click "save parameter"to exit from the setting interface.
4.Pre and hold the left on for more than 4 seconds,the symbol lights to start recording.Click the icon "upload data"to view the data.
5. Log out the data management software.
About shping
This product has no ratings yet.
Subscribe to our newsletter
and be the first one to know about our amazing deals!