Package : SOPis_customized : YesModel Number : Battery Charge Discharge ModuleOperating Temperature : -25 ~ 85 CelsiusSupply Voltage : DC 6-60V/ 6-40V/ 12-36VApplication : MOBILE PHONECondition : NewType : Logic ICsBrand Name : IS : Mainland ChinaInput Voltage : DC 6-60V/ 6-40V/ 12-36V/ 12VWork Current : 10A/30AFeature 1 : Battery Charge Discharge ModuleFeature 2 : Low Voltage DisconnectFeature 3 : Low Voltage Cut OffFeature 4 : 12V Battery Charger Controller ModuleVersion 1 : DC 6-60VIntroduction:1.Name: battery charging control module2.Model: XH-M6043.Input Voltage: DC 6-60V4.Display Precision: 0.1V5.Control Precision: 0.1V6.Output Type: direct output7.Voltage Tolerance: +/-0.1V8.Application Fields: 6-60V storage batteryUsing Method:1.Set Starting Voltage: in normal display voltage state,press the on will display start charging voltage; press for 3s the digital tube will flash;you can start or stop on to set starting up charge voltage value2.Set Stop Voltage: in normal display voltage state,press the on will display stoping charge voltage; press the on for 3s the digital tube will flash;you can start or stop on to set stoping charge voltage value3.Factory Reset: in power on state press the start/stop on at the same time,digital tube will display 888;that represents factory reset settingsVersion 2: DC 6-40VModule Highlights:1. Battery charge and discharge intelligent control;2. You can set the charge and discharge time;3. With serial communication function, real-time monitoring of the working status of the relay through the serial port;4. Additional signal output, when the relay to meet the conditions, the output high, you can control other equipment.5. A key emergency stop function (STOP on), with reverse protection, reverse does not burn.Operating mode:Voltage upper limit: UL1, voltage lower limit nL1, the voltage upper limit is greater than the voltage lower limit (UL1> nL1)U-1:?Charging measurement: When the measured voltage is lower than the lower limit voltage, the relay pulls above; the upper limit voltage, the relay is disconnected.U-2:?charge measurement time control: set the charging time (OP); when the measured voltage is lower than the lower limit voltage, the relay pull, and then start the countdown OP time, the end of the timer, the relay off; when the measured voltage is higher than the upper limit voltage , The relay is disconnected.U-3:?Discharge detection: When the measured voltage is lower than the lower limit voltage, the relay is off, above the upper limit voltage, the relay pulls;U-4:?discharge detection time control: set the discharge time (OP); when the measured voltage is higher than the upper limit voltage, the relay pull, and then start the countdown OP time, the end of the timer, the relay off; when the measured voltage below the lower limit voltage , The relay is disconnected;U-5:?voltage in the range, the relay pull: when the measured voltage between the upper and lower limits, the relay pull, the other circumstances open;U-6:?voltage outside the interval, the relay pull: the measured voltage below the lower limit voltage or higher than the upper limit voltage, the relay pull, the other case the relay is off.:1: Power supply voltage: DC6--40V, voltage detection range DC 0--60V, suitable for less than 60V of the various batteries, voltage measurement error ± 0.1V.2: charge and discharge time (OP) range: 0 - 999 minutes.How do I set ?1. First, according to their needs, to determine the requirements of the work model;2. According to the working mode of the relay, in the main interface (when the module is powered on, it will flash the current mode of operation, the default U-1 mode, and then enter the main interface) press the SET on for 2 seconds and then release, enter the selection Mode interface, UP, DOWN on to select the mode to be set (U-1 ~ U-6);3. After selecting the mode, assume that we have selected the U-1 mode and press the SET on to set the corresponding parameter. The parameter to be set will flash (UL1 voltage upper limit, nL1 voltage lower limit, OP conduction time), press UP, DOWN Key to increase or decrease, you can always press the key to quickly increase or decrease, press the SET on to set the current mode of the next parameter, the process above;4. Set the , and then press the SET on for 2 seconds to release, the current setting mode will flash, and then return to the main interface, set the of success!5. In the main interface, press the DOWN key to achieve voltage and time switching.Mode selection interface:?press the SET on for a time to enter the mode selection interface, set the finished, a time press the SET on and then release the exit mode selection interface, back to the main interface.Additional features:1. Data upload: through the serial port to achieve data upload, interval 1s upload a voltage and run time, easy to post-data analysis;2. Serial port settings : You can set the mode and through the serial port, more convenient;3. An extra signal output, when the relay to meet the conditions, the output high, the other output low.Serial port control (TTL level communication)Communication standard:The baud rate is 115200 bpsData bits: 8Stop bit: 1Check digit: noneFlow control: noneSerial command:"U-1": Operating mode (range U-1 to U-6)"000": 0 - does not enable timing function, non-0 - enable timing function (range 001 to 999)"Dw02.9": Set the lower limit voltage"Up10.1": set the upper limit voltage (range 00.0V ~ 99.9V)"Get": Get the current settings"On": Allows the relay to turn on"Off": Always turn off the relay"Start": start uploading data"Stop": stop uploading dataThe above command can be any combination of two, need to be separated by commasSuch as: "dw02.9, up10.1" set the lower limit voltage 02.9V upper limit voltage 10.1VUpload Status: Test Voltage + On Time + Status"00.0V, 00: 00: 00, OP \ r \ n"00.0V: Measured voltage00:00:00: Relay on timeStatus: OP relay on, CL relay offSTOP key function expansion:Relay enable mode:1. ON: OP conduction time, the relay allows conduction;2. OFF: The relay is disabled and is always off;Press the STOP on on the main interface to switch between ON and OFF, the current status will flash, and then return to the main interface. (This function is an emergency stop function, a key to disconnect the relay)Sleep mode:1. C-P sleep mode: within five minutes, without any operation, the digital tube automatically shut down the display, the program normal operation;2. O-d normal mode: digital tube is always open display;Press and hold the STOP on for 2 seconds to release, to achieve C-P and O-d state of the switch, the current state will flash, and then return to the main interface.Version 3: DC 12-36VVersion 4 : DC 12V 30AIntroduction:XDC02 is a battery undervoltage control module.The load is automatically disconnected when the battery is under voltage,and is automatically connected when the battery is over voltage.Feature:1>.Parameter memory function2>.Automatic recovery function3>.Real-time display voltage4>.12V battery only5>.Load power-off delay protectionParameter:1>.Product Name:Battery Undervoltage Control Module2>.Model:XDC023>.Input Voltage:12V(only use 12V battery)4>.Voltage Accuracy:0.1V5>.Input Current:30A(MAX)6>.Scope of Application:Storage Batteries or Lithium Batteries7>.Work Temperature:-25℃~85℃8>.Work Humidity:5%~95%RH9>.Size:70.5*50.5*24.5mmNote:1>.The product has a 6-second time delay to avoid disconnecting the load when the battery voltage drops when the large battery starts.2>.The product can only be connected to a 12V battery. Don't connect other types of batteries.on Setting:1>.Stop on:Set Undervoltage on1.1>.Short press Stop on to display the current set Undervoltage Parameter Value.1.2>. press Stop on the display flashes.Press Stop on and Start on to setting the Undervoltage Value.2>.Start on:Set Overpressure on2.1>.Short press Start on to display the current set Overpressure Parameter Value.2.2>. press Start on the display flashes.Press Stop on and Start on to setting the Overpressure Value.3>.For Example:The module is connected to a 12V battery,the set undervoltage is 10.5V,and the set overvoltage is 12V.It means that when the battery voltage is lower than 10.5V,the load is turned OFF,and when the battery is higher than 12V, the load is turned ON.