Product sellins:
1. High stability
2. Strong reliability
3. Long service life
4. Accuracy error calibration with adjustable potentiometer
5. User defined high and low voltage range: DC8-100V
6. Measurement of ternary lithium battery L from L03 series to L20 series (power off memory)
7. Lead acid battery P measurement: DC12V, 36V, 48V, 60V72V, 84V (power off memory)
8. Measurement of lithium iron battery F from F03 to F23 (power off memory)
Product parameters:
Voltage detection range: DC8-80V
Working current: ≤ 15MA
Display mode: LCD screen
Display color: blue/white/color (optional)
Performance index:
Detection accuracy: ± 1%
Opening size: 58.5 * 28.5MM
Refresh speed: 500ms/time
Boundary dimension: 61.3 * 33.3 * 13.5MM
Packing list:
1 x Battery Capacity Indicator
1 x Cable Lead
Model specification
Long pre the upper right corner on on the home screen for 2 seconds to enter the mode Settings page, and long pre the upper right corner on for another 2 seconds to exit the Settings page and return to the home screen
Mode 1 - Lead acid P setting;
Mode 2 - ternary lithium L setting;
Mode 3 - Lithium iron F setting;
Mode 4 -- Custom high and low voltage Settings: Custom low voltage and saturation voltage,
display 00.0 000, left digit is the low voltage parameter, right
The number is the saturation voltage parameter;
Mode 5-- backlight setting: Display 5-B, short pre the on in the lower right corner to
switch ON/OFF, ON is to automatically turn OFF the backlight after 10S delay, OFF is
The backlight is always on;
Mode 6- low voltage alarm Settings: display 00.0V Lo, the left is the alarm voltage parameter
(voltage below this parameter alarm);
Mode 7-- alarm sound setting: Display 7-A, short pre the on in the lower right corner to
switch ON/OFF, ON is to open the alarm sound function, OFF is to shut downAlarm sound function (this function needs to be selected when purchased)
Note: there are two kinds of lithium batteries (ternary lithium L and iron lithium F), teach you to distinguish;First charge the battery first, a string of three yuan lithium batteryThe saturation voltage is DC4.2V, and the saturation voltage of lithium iron battery is DC3.6V.For example: saturation voltage shows 84V (20 strings), this one
It is a ternary lithium battery, and then select parameters according to the setting mode of ternary lithium battery
Parameter Settings
Lead-acid battery
In the lead-acid battery setting page, the voltage value flickers, short pre the on in the lower right corner to select the battery voltage that needs to be used, after selecting the voltage, the short.
Ternary lithium
In the ternary lithium battery setting page, the number of battery strings is flashing, and the number of battery strings to be used is selected by preing the on in the lower right corner. After selecting the number of battery strings, pre the on in the upper right corner to confirm and save the value ( the number of battery strings is always bright ), pre the on in the upper right corner for 2 seconds to return to the main page, or pre the on in the upper right corner for other mode settings.
iron lithium battery
In the ternary lithium battery setting page, the number of battery strings is flashing, and the number of battery strings to be used is selected by preing the on in the lower right corner. After selecting the number of battery strings, pre the on in the upper right corner to confirm and save the value ( the number of battery strings is always bright ), pre the on in the upper right corner for 2 seconds to return to the main page, or pre the on in the upper right corner for other mode settings. Lithium iron battery
Custom high and low voltage settings
On the user-defined high and low voltage setting page, 00.0 on the left side is low voltage, 000 on the right side is saturated voltage. Short pre the key at the lower right corner to set the bit value. After the bit value is set, long pre the key at the lower right corner for 2 seconds to shift. After the low voltage and saturated voltage are set, short pre the key at the upper right corner to confirm and save the value (all values are always on), long pre the key at the upper right corner for 2 seconds to return to the main page, You can also pre the key on the upper right corner briefly to set other modes.
T : the right side of 000 is actually 00.0, such as 255 shows is 25.5
Display backlight settings
On the backlight setting page, ON/OFF flashes. Briefly pre the on at the bottom right corner to select ON or OFF. ON: The display automatically closes after a 10 second delay. OFF: The display is always on. Briefly pre the on at the top right corner to confirm and save the options. Long pre the on at the top right corner for 2 seconds to return to the main page. You can also briefly pre the on at the top right corner to set other modes.
Low voltage alarm settings
On the low voltage alarm setting page, 00.0 on the left is the setting value. Short pre the key at the lower right corner to set the bit value. After the bit value is set, long pre the key at the lower right corner for 2 seconds to shift. After the alarm voltage is set, short pre the key at the upper right corner to confirm and save the value (all values are always on). Long pre the key at the upper right corner for 2 seconds to return to the main page, or short pre the key at the upper right corner to set other modes.
Note : If the user does not customize the low voltage alarm parameters, the product default power is le than 10 % automatic alarm prompt.
Alarm sound setting
On the alarm sound setting page, ON/OFF flashes, short pre the on at the lower right corner to select ON or OFF, ON: turn on the alarm sound, OFF: turn off the alarm sound, short pre the on at the upper right corner to confirm and save the options, long pre the on at the upper right corner for 2 seconds to return to the main page, or short pre the on at the upper right corner to set other modes.
Note : This product is a patent product of our company, please do not imitate, imitation must be investigated.