Portable Nebulizer machine Product Descrtion
◆ The N1 mesh r is mainly composed of a piezoelectric component. The piezoelectric component converts electrical energy into mechanical energy and generates ultrasonic vibration. The vibration squeezes the liquid in the medicine cup, and the liquid paes through the micro-spray of the sprayed piece. The hole s the liquid and ejects it from the sprayed piece to the mouthpiece or for use by the inhaler.
◆ Scope of application: d drugs for the treatment
Features
1. Effective treatment, atomization at any time at home.
2. Low residual liquid, ≤0.5mL.
3. Low noise design, the actual sound perception is lower than 50db, which is almost impoible to perceive.
4. DC power supply & AA battery power supply, more convenient to use.
5. Food grade material .
6. The maximum capacity of the medicine cup is 8ML, which can be adapted to different liquids.
1. Эффективное лечение, распыление в любое время в домашних условиях.
2. Низкое содержание остаточной жидкости, ≤0,5 мл.
3. Малошумный дизайн, фактическое восприятие звука ниже 50 дБ, что практически невозможно воспринять.
4. Питание от источника постоянного тока и батарейки AA, более удобные в использовании.
5. Маска из пищевого материала.
6. Максимальная емкость чашки для лекарств составляет 8 мл, которая может быть адаптирована к различным жидкостям.
Portable.Silent.fine fogg
Портативный бесшумный небулайзер
CE certification
After s Guarantee
Послепродажная гарантия
1-5um!Reach aeoli
The average diameter is ~3 um,which can be directly absorbed
by the aeoli and can be used to treat lower respiratory tract diseases
1-5 мм! Достигают альвеол
Средний диаметр ~ 3 мкм, который может быть непосредственно поглощен
альвеолы и могут быть использованы для лечения заболеваний нижних дыхательных путей
Quiet!Baby sleep at ease
The actual use of sound perception is le than 40db, almost impoible to perceive
Тишина! Малыш спит спокойно
------Фактическое использование восприятия звука составляет менее 40 дБ,почти невозможно воспринять
d like in the hospital
Suitable for nebulization treatment of lower respiratory tract diseases
Небулайзер с тем же эффектом, что и в больнице
Rapid atomisation
0.35ml/min Fog out rate
The fog rate is stable at 0.35ml/min.It is not easy to choke the throat
It only takes 15 minutes to 5ml medicine
Быстрое распыление
Скорость выхода тумана 0,35 мл/мин
Скорость тумана стабильна на уровне 0.35 мл/мин. Не легко задохнуться в горле
Для распыления 5 мл лекарства требуется всего 15 минут
non-choking throat
Atomization rate : ≥0.2Ml/min
grade atomization rate 0.2Ml/min ,Smooth, non-choking throat ,Provides smooth treatment for children
Хорошо для горла
Скорость распыления: ≥0,2 мл/мин
Скорость распыления медицинского класса 0,2 мл/мин
Гладкое, не колющее горло , Обеспечивает плавное лечение детей
Safer for children
CE approved mesh nebuliser reduces residue
Prevents drug spillage
Безопаснее для детей
Сетчатый небулайзер с медицинским сертификатом CE уменьшает количество остатков лекарства
Предотвращает проливание лекарств
Low drug residues
90° design of medicine cup, suitable for various nebulization method
Efficient drug atomization, directly to the lesion .Low residual 0.1ML
Низкое содержание остатков лекарственных препаратов
90° дизайн чашки для лекарств, подходит для различных методов небулизации
Эффективное распыление лекарства, непосредственно на очаг поражения .Низкий остаток 0,1 мл
Fully dismantled desigen
Fully detachable design, easy to clean
Съемная конструкция
Полностью съемная конструкция, легко моется
Small nebulizer, large capacity - 8ml medicine cup
Маленький распылитель с большой емкостью-- стаканчик для лекарств 8 мл
Suitable for everyone
1. Kids 2. Adult 3. The elders 4. Patients Cough, Asthma,Bronchitis,Get Cold
Подходит для всех
1. Дети 2. Взрослые 3. Старики 4. Пациенты с кашлем, астмой, бронхитом, простудой
Portable one-hand operation
Портативное управление одной рукой
Nebuliser Acceories
Аксессуары для небулайзеров
Main unit: 1 set
Medication cup module: 1 set
Mouthpiece: 1pc
English Manual : 1pc
Warranty card: 1pc
Storage bag: 1pc
s: 2PCS (one for adults and one for children)
If you need further acceories, please contact the supplier。
Easy to use
Простота в использовании
1. Power: 3V DC ( 2 x "AA" 1.5V alkaline batteries)
2. Net weight: About 110g (without battery)
3. Atomization rate: ≥0.2Ml/min
4. Size: L125mm x W 47mm x H41mm
5. Residual liquid amount: ≤0.5Ml
6. Inlet protection rating: X3
7. Noise: ≤50Db(A)
8. Contraindications: None
9. Nominal frequency: 108kHz
10. Operation mode: Continuous operation
11. Use period: 5 years (except for vulnerable parts)
12. Distribution of the equivalent volume particle size: median particle
size 3.7um ± 25%, the diameter of fewer than 5 microns, fog particle occupancy ratio
of not le than 60%.
13. Continuous operating time: More than 1 hour (use 2 x new "AA" 1.5V alkaline batteries)
14. Safety claification: Equment that cannot be used in the
presence of flammable anesthetic gas mixed with air or flammable anesthetic gas mixed with oxygen
or nitrous oxide.
15. Electrical safety requirements: internal power supply equment, type B application
16. Normal operating conditions: Temperature range: 5 ° C ~ 40 ° C Relative humidity range: 15% ~ 93% Atmospheric preure range: 86k Pa~106k Pa
17. Transportation and storage environment restrictions:Ambient temperature range: -40°C~+55°C Relative humidity range: 10%~93% Atmospheric preure range: 70k Pa~106k Pa
18. Distribution curve of the particles’ equivalent volume size (ambient temperature 23 ° C ± 3 ° C, relative humidity 45% ~ 65% environment): ※ Test conditions: ambient temperature to be set at 23 ± 2 ° C, relative humidity to be set at 53%, use 0.9% physiological saline and our company's instrument test. (Test data may vary with test conditions and liquids) When the storage temperature is lower than 5 °C, the equment should be returned to normal operating conditions before use! Store in a well-ventilated room and avoid vibrations during transportation. Note: Ambient temperature range: -40°C~+55°C Relative humidity range: 10%~93% Atmospheric preure range: 70k Pa~106k Pa
Step explanation
①istall battry
1.With the bottom of the nebulizer main unit facing up, open the battery cover and insert the battery.
2.Insert the battery according to the polarity identification
3.Close the battery cover
Note:
1. Do not mix different types of batteries.
2. When the indicator light (in red) flashes, it indicates that the battery is almost used
up. Please replace the alkaline battery as soon as poible.
3. When the indicator light (in red) is permanently on, it indicates that the battery i
used up and the r cannot be used to spray. Please replace the new alkaline
battery immediately.
4. When the indicator light (red light) is steady, it indicates that the battery i
exhausted and the r cannot be sprayed. Please replace the new alkaline
battery immediately.
5. When not using the nebulizer for a long time, remove the battery
②Remove the vial module from the nebulizer
After preing the PUSH on on the back of the main unit, push the medication cup toward .the front of the main unit and remove the medication cup module.
Note
1.When removing the medication cup module from the r, please confirm that the PUSH on is preed and then push the medication cup module to avoid damage to the r.
2.Do not insert your fingers or other objects from the spout area, nor touch the spray film to avoid causing damage to the film
1.Add a minimum of 0.5Ml of liquid medicine and no more than 8mL.
2.Be sure to follow the doctor's instructions to choose the type of liquid, the dosage and how to use it.
3.After adding the liquid, close the cup lid to prevent the liquid from leaking out.
4. Do not shake or carry the nebulizer with your medicine or other liquid in the medicine cup.
5. When using high concentration, high viscosity, suspension liquid, and volatile liquid, please follow the doctor's advice.
③Aemble the cup mold back to the nebulizer main unit and confirm that the installation is in place.
Note
1. Please make sure that the cup module is aembled (you can hear a slight “beep” sound, indicating that the buckle has been buckled), to ensure that the electrode is in good contact and can be used to spray normally. Push
2. Keep the main unit and the cup electrode clean, otherwise, the nebulizer may not spray properly
④Install a mouthpiece or
Note
1. When using the or the mouthpiece for the first time, wash it with pure water and dry it
before use.
2. In addition to and optional it, use a and mouthpiece approved by the
company.
⑤Pre the switch to start the nebulizer and inhaler.
1. The nebulizer automatically shuts down when the cup does not contain any liquid or other liquid.
2. When the liquid is exhausted and there is no liquid contact with the sprayed piece,
the r will automatically turn off after flashing in red.
3. Since there are liquids of different characteristics, the r cannot be automatically turned off when some of the liquid is exhausted. At this time, the switch should be turned off immediately, turn off the r to avoid damage to the sprayed piece.
4. When the liquid is about to run out, it is recommended that the user tilts the front of the nebulizer (the side with the on) slightly toward himself to facilitate the atomization of the remaining liquid that is in contact with the spray.
5. After preing the switch, the nebulizer will go through a short start-up period (within 2 seconds) before spraying normally.
6. When using the for inhalation, do not cover the venting holes with your hands or other objects.
7. When holding the atomizing inhalation, hold the nebulizer smoothly by hand. There is a venting hole on the lid of the medication cup. Do not cover it with your hands or other objects or normal spraying function will be affected.
8. If the user feels any discomfort during the atomization proce, please turn off the machine immediately and consult a doctor promptly.
Note1. During the atomization, some of the liquid will be concentrated in the vicinity of the spray film in the medication cup, which will easily cause the sprayed piece to vacate and cause damage to the sprayed piece. At this time, please pre turn off the r, shake the main unit slightly, and restart.
⑥Turn off the power 1. When the liquid is exhausted, the r will flash in red and automatically shut down. 2. If you need to stop using it during use, you can turn off the power by preing the start switch. The nebulizer indicator (in blue) will go out. ⑦Cleaning and maintenance after use Clean up the remaining liquid ◆ Remove the mouthpiece or from the cup ◆ Open the cup lid and drain the remaining liquid ◆ Add a small amount (2-5 mL) of pure water to the cup and close the lid. Gently shake the cup to dioe the residue in pure water. ◆ Add a small amount (2-5 mL) of pure water to the cup and close the lid. Gently shake the cup to dioe the residue in pure water. ◆ Open the cup lid and pour off the solution in the cup, add a small amount (2-5mL) of purified water. ◆ Keep preing the start on until the indicator light flashes alternately. At this time, the r enters the cleaning mode, and the pure water is d and sprayed to clean the residual liquid on the sprayed piece. Note 1. Always remove the battery before cleaning and maintenance 2. The cup module is a consumable part and no warranty is provided. Under normal cirstances, the life span of the cup is half a year (3 times a day in a normal temperature environment or 30 minutes per day). The mechanical life of the cup varies with the medication used. 3. If the residual liquid is difficult to be removed, it can be washed with hot water or washed repeatedly. 4. Be sure to clean the remaining liquid after each use, otherwise, it will cause the r spray piece to clog and affect the atomization effect. 5. The cleaning mode is only used to clean the spray film after atomization is completed, and it cannot be used for normal liquid atomization. Cleaning ◆ Main unit: use a damp gauze, gently we the stain on the main unit and dry it with a new gauze. ◆ Clean the electrodes on the main unit and the cup unit to ensure good connection of the cup module to the main unit. Note 1. Do not we the mesh nebulizer with a volatile liquid such as benzene, benzine or thinner. 2. Do not use a cotton swab or other it to touch the electrodes on the main unit and the medication cup module, causing them to fall off. 3. Remove the battery before cleaning the parts. ◆ Cup module and inhalation device: Clean the cup module and inhalation device with pure water ◆ Dry the cleaned parts with new gauze and place them in a clean place to dry thoroughly. Note 1. Do not use cotton paper or other cloth to we the cup module to prevent residual paper dust or cloth from getting into contact with the cup and clogging the sprayed piece, resulting in fai to spray properly. 2. Do not use cotton swabs or other it to get into contact with the spray film. 3. Do not use any other detergent or tap water to clean the cup or other parts except pure water. ◆ Place all parts of the nebulizer in a clean place
Note
1. please rinse thoroughly with pure water to avoid alcohol and acetic acid residue.
2. Do not let the main unit, the cup module fall or be shocked.
3. Do not poke the nebulizer with a needle or other sharp object
4. Do not place the main unit and other components in extreme heat, cold or under direct sunlight.
5. Do not plug and unplug the power adapter with wet hand
6. This product should be purchased and used under the guidance of a doctor.
7. When storing or using the nebulizer, keep it out of reach from children or people
with mental illnees. They can only use the device under the supervision of an adult
8. The nebulizer can be used by many people but the acceories (, mouthpiece)
that come into contact with the human body are limited to the same person to
prevent cro-infection. If more than one person uses more than one acceory
for the main unit, the main body and the acceories should be stored separately.
9. Do not disaemble the main unit and try to repair it yourself.
10. Do not store the nebulizer if there is medicine or water in the medicine cup
⑨After-s service
1. If probl caused by non-human factors occur within one week from the date of purchase,our company can offer return, replacement, and maintenance. Given that the use and conditions of storage are normal,if there are any iues related to the quality of the product within one year from the date of purchase,our company will provide free maintenance. If there are any probl with the quality of the product after one year after the date of purchase,according to the invoice and warranty card, the user can visit the after-s service department, office or dealer of the company,and our company will provide parts for maintenance with reasonable charges。If the user cannot provide the invoice,the maintenance date is set as one month after the production date.
2. The following conditions are not covered by the warranty:① components that are
worn-out easily:medication cup module、suction device;② technical errors caused by disaembly, repair and of the product without authorization;③ Faults caused by dropping the device carelely in the proce of use and move;④ Faults caused by improper use;⑤ Getting water, medicine,and other liquids into the main unit, causing it to malfunction;⑥ Faults caused by fai to operate the device according to the instructions;⑦ Faults caused by unforeseen natural disasters (such as fire, earthquake, flood, etc)
3. If neceary, the user may be required to provide a circuit diagram and neceary information for
repair. If there is any problem in repairing the electrical circuit, contact the manufacturer.
PAYMENT
>> , Web Money, Visa, MasterCard, , Maestro debit card, Boleto and transfer optional recently; >> More payment will be available on Aliexpre in the future.
SHPING
>> To protect both the buyers and sellers, it will take about 24 hours for to verify the payment. After verification, all the it will be sent out within 3 days but as soon as poible; >> Please confirm your ORDER ADDRESS CORRECT,or you will take responsibility for any fees caused from the wrong addre. >> Free shping for most of it, but for some countries, you may pay some extra shping cost.Gene -rally speaking, the delivery time is 20-60 days. If you need faster shping, please contact us in advance.
About shping
This product has no ratings yet.
Subscribe to our newsletter
and be the first one to know about our amazing deals!