Key Features
Digital Protractor Angle Finder Inclinometer Electronic Level 0-90° Inclinometer Slope Scale Ruler Bubble Magnetic Level Ruler
USD 8.54-21.34/piece
Magnetic Welding Holders 45° 90° 135° Multi-angle Solder Arrow Magnet Weld Positioner Locator Holding Auxiliary Locator Tools
USD 7.79-13.48/piece
20/30/45cm Aluminum Straight Ruler Multifunctional Protective Ruler Anti Slip Laser Calibration Hands Marking Ruler for Woodwork
USD 1.19-3.82/piece
Garden Auger Spiral Drill Flower Pot Auger Ground Drill Portable Garden Greenhouse Digging Hole Loosening Tool Auger Accessories
USD 1.96-4.55/piece
Bearing Roller Type Tube Cutter Professional Pipe Cutter Metal Scissor Pipe Cutter Stainless Steel Copper Tube Cutting Tools
USD 1.64-15.05/piece
YS9901/YS902 Digital Chess Timer Professional Chess Clock Multifunctional Digital Count Up Count Down Precision Game Stopwatch
USD 10.57-10.79/piece
SK120 Numerical Control Lift Voltage Regulator DC Adjustable Power Supply Constant Current CC CV 6A 120W Solar Charging Module
USD 10.79/piece
Waterproof and Dropproof Instrument Toolbox Portable Hard Carry Case Bag Impact Resistant Tool Case with Sponge Safety Protector
USD 5.50-8.65/piece
Digital Socket Tester US EU UK Voltage Test Socket Detector Smart Detector with HD Backlit Screen Leakage Protection Detection
Feature:
SOCKET WIRING SEQUENCE TEST: Insert the tester into a standard three-pin power socket. If a wiring sequence error is detected, the orange backlight will illuminate to indicate a wiring error. Refer to thedisplay to identify the specific type of wiring error.
DATA RETENTION: After inserting into the socket, the data automatically locks after three seconds. Once locked, press the unlock button to release the data.
LEAKAGE SWITCH DETECTION: Insert the tester into a three-pin socket, ensuring that the display indicates correct wiring. Press and hold the RCD button for more than 2 seconds. In this case, a functioning residual current device (RCD) should trip, displaying the ripping time. The button indicator willflash, indicating the completion of the tripping process. If it does not trip, it suggests a malfunction in the residual current device.
AUTOMATIC SHUTDOWN: If there is no operation within 5 minutes of powering on, the instrument will automatically shut down.
PRODUCT SAFETY AND RELIABILITY: Rated safety level CAT II 300V ensures safe usage and quality assurance.
HIGH-DEFINITION BACKLIT LARGE SCREEN: The high-definition backlit display screen ensures clear visibility of measurement content even in dimenvironments, providing a clear and easily understandable view of the test results.
WIDELY APPLICABLE SCENARIOS: Can be used to inspect the safety of socket wiring in homes, offices, shopping malls, and other places.
Specification:
Voltage range: AC 30-260V/45-65Hz,± (2.0%+2)
Leakage voltage range: 0~99V/45~65Hz, ± (2.0%+2)
Trip time test: 10-1000mS, ± (2.0%+4)
GFCI test: >5mA(Only for HT97B)
RCD test: >30mA(Only for HT97D/HT97E)
Voltage measurement (48V-250V/45-65Hz): Yes
LCD display: Yes
Backlight: Yes
Socket connection detection:
1.10-1000mS, ± (2.0%+4)
2. Open ground
3. Open neutral
4. Open live
5. Live wire and ground wire reverse
6. Live wire and neutral wire reverse
7. Live wire and ground wire reverse, missing ground wire
Power supply: 2x1.5V AAA batteries(The battery is not included in the product)
Size: 67mm x 65mm x 63mm
Safety rating EN61010-1,-2-030; EN61326-1, CAT II 300V
Package include:
1*Socket Tester
1*User Manual