HomeHome & OfficeTools & Home ImprovementElectricalTestersBattery TestersDC6-60V Solar Battery Charger Controller Module XY-CD60 Charging Discharge
product_image_name-Generic-DC6-60V Solar Battery Charger Controller Module XY-CD60 Charging Discharge-1

Share this product

Shipped from abroad

DC6-60V Solar Battery Charger Controller Module XY-CD60 Charging Discharge

GH₵ 289.00
GH₵ 498.0042%

In stock

Order above GHC 150 on Jumia Express items & get free delivery | regular delivery from GH₵ 36.89 to Tema
0 out of 5
(No ratings available)

Promotions

Delivery & Returns

Shipped from abroad 

Choose your location

Pickup Station

Delivery Fees GH₵ 36.89
Ready for pickup between 17 December and 20 December if you place your order within the next 2hrs 17mins

Door Delivery

Delivery Fees GH₵ 48.79
Ready for delivery between 17 December and 20 December if you place your order within the next 2hrs 17mins

Return Policy

Free return within 15 days for all eligible items.Details

Seller Information

Noarlall

86%Seller Score

15 Followers

Follow

Seller Performance

Shipping speed: Average

Quality Score: Excellent

Customer Rating: Excellent

Product details

Descrtion: This Product is a battery charge and discharge controller module. It can be used for DC 6 -60V lithium/lead-acid battery. Feature: Multi-function test instrument Dual mode work Support charging protection Support discharge protection Support set the charging/discharging time Automatic detection parameters HD LCD display Multi-parameter display Support power saving mode Supports automatic battery detection Comfortable outer casing Parameter: Product name: Lithium Battery Charging/Discharging Controller Model: XY-CD60 Working voltage: DC 6 -60V Prevent Over-charge Prevent Over-discharge Display battery voltage, percentage and operating time. Charging Time Control: 00:00 -99:59 hours Discharging Time Control: 00:00 -99:59 hours Delay: 0 -999 seconds Work Temperature: -40 -85℃ Work Humidity: 0% -95%RH Size: 79*43*27mm Function: Module supports 2 working modes:  Charging Control P-1 and Discharging Control P-2. Charging Control P-1: This mode is used for charging control to prevent overcharging. Display symbol IN indicates charging mode. Discharging Control P-2: This mode is used for battery discharge control to prevent battery over-discharge and delay battery life. Display symbol OUT indicates discharging mode. Battery voltage percentage: It is value get from battery voltage V, Lower Limit Voltage Value DOWN and Upper Limit Voltage Value UP. Calculation formula: V/(UP-DOWN). Automatic parameter check: Screen will display and flashing ERR if the Lower Limit Voltage Value DOWN is more than the Upper Limit Voltage Value UP. [Charging Control P-1 Mode] Input terminal connect DC 6V-60V charger which use for battery. Output terminal connect 1pc of DC 6 -60V battery. It will display 0.00V and nbE if the battery does not meet the requirements. Output turn ON and the input charger starts charging the battery if battery voltage is le than the Lower Limit Voltage Value DOWN. Output turn OFF and the input charger stops charging the battery if battery voltage is more than the Upper Limit Voltage Value UP. The symbol IN will flashing when charging. Support set parameter: Upper Limit Voltage Value UP: Maximum voltage of the battery. Stop charging the battery if it exceeds this value. It is also the overcharge protection voltage value. Lower Limit Voltage Value DOWN: Battery allowed minimum voltage. Start charging the battery when the battery voltage is lower than this value. Charging Time OP: Set battery charging time. Turn ON charging time control function when the OP parameter value is more than 00:00. Minimum set time value 1minute. Turn OFF OP control if set 00:00. Start the timer when turn on output to start charging. Module turn OFF output to complete a charging proce when timing is completed. Module automatically turns OFF charging time control function if battery voltage is le than the Lower Limit Voltage Value down and flashing H:ER that means the unreasonable time parameter setting. It means insufficient charging and needs to continue charging the battery. Pre any key to stop flashing. Record and display charging time if disabled Charging Time OP when short pre on SET. Clear time if at next charging or exit charging time display interface. Turn ON Delay Time DOP: Set the delay interval between the first and the second charging. The time range is 0 -999second. [Discharging Control P-2 Mode] Input terminal connect 1pc of DC 6 -60V battery. Output terminal connect suitable load. Note the output voltage is same to battery. Output turn ON and the battery starts to discharging if battery voltage is more than the Upper Limit Voltage Value UP. Output turn OFF and the battery stops to discharging if battery voltage is le than the Lower Limit Voltage Value down. The symbol OUT will flashing when discharging. Support set parameter: Upper Limit Voltage Value UP: Threshold value to allow battery discharge. Lower Limit Voltage Value down: Battery allowed minimum voltage. Stop discharging when the battery voltage is lower than this value. It is also the over-discharge protection voltage value. Discharging Time OP: Set battery discharging time. Turn ON discharging time control function when the OP parameter value is more than 00:00. Minimum set time value 1minute. Turn OFF OP control if set 00:00. Start the timer when turn on output to start discharging. Module turn off output to complete a discharging proce when timing is completed. Module automatically turns OFF discharging time control function if battery voltage is more than the Upper Limit Voltage Value UP and flashing H:ER that means the unreasonable time parameter setting.  Pre any key to stop flashing. Record and display discharging time if disabled Discharging Time OP when short pre on SET. Clear time if at next discharging or exit discharging time display interface. Turn ON D image image image image image About shping
Shping and Packaging All it will be double checked and well packed before sending.It will be dispatched within 2 business days after buyers pay for the order. It usually takes about 14 to 18 working days for delivering the package to the destination(for e areas,it may take a little longer). 

Special Announcement:
Please fill in the correct and detailed consignee, address and phone number in the order. For fast and correct delivery.If you do not receive order within 30 working days,please feel free to contact Customer Service before leaving Negative and Neutral Feedback, we will do our best to help you resoe the problem.TaxNo, you will only pay what is quoted as total cost at checkout, no more. You are not expected to pay any additional duties or taxes. If you are asked by Customs or our logistic partner to pay duties, please contact our Customer Service .

Your 100% satisfaction is very ant to us
If the product is not on good condition, You can return this product within 14 working days, please contact customer service center before returning.FeedbackYour satisfaction is our first priorityIf you receive the order and it is in good condition,we would be grateful if you would leave us 5 star Positive Feedback for the transaction.

Specifications

Key Features

  • Model Number:Charge Controller
  • Type:Electronic Device Battery Tester
  • DIY Supplies:ELECTRICAL
  • Certification:NONE
  • Origin:Mainland China
  • Control voltage:6-60V

What’s in the box

1X DC6-60V Solar Battery Charger Controller Module XY-CD60 Charging Discharge Control Low Voltage Current Protection Board

Specifications

  • SKU: GE779IP1Q1ZDZNAFAMZ
  • Model: NOAdianchiceshiyi2358
  • Production Country: China
  • Size (L x W x H cm): 10*10*10
  • Weight (kg): 0.2
  • Main Material: PVC

Verified Customer Feedback

This product has no ratings yet.

DC6-60V Solar Battery Charger Controller Module XY-CD60 Charging Discharge

DC6-60V Solar Battery Charger Controller Module XY-CD60 Charging Discharge

GH₵ 289.00
GH₵ 498.0042%
Questions about this product?

Recently Viewed

See All