Our shop sells the most popular 3C consumer electronics products,such as mobile phone accessories,computer accessories,game peripherals,smart wearables,and follow the most popular fashion trends. If you like our products,please follow us,become our follower and fan.We will provide you with the most popular products to satisfy your fashion shopping experience.Brand Name : NoEnName_Null
High cost performance programmable CNC adjustable step-down power supply module
(DIY desktop CNC small power supply, you can easily do it yourself)
1. Baby highlights:
1.1 LCD can display input/output voltage, output current/output power/output capacity/output time;
1.2. CNC adjustment, accurate and fast, can boost and lower voltage, output voltage can be adjusted at will from 0.5-30v, limit current 0-4a can be adjusted at will;
1.3. Anti-reverse connection protection of input end, which will not burn out;
1.4. Anti-reverse irrigation at the output end, no additional anti-reverse irrigation diode is needed to charge the battery;
1.5. The module can be set to open/close by default;
1.6. Multiple software protection mechanisms are available, and the protection threshold is adjustable.When the working of the module exceed the protection threshold, the output will be automatically closed.
1.6. Output ripple is small and PI filter is available;
1.8. Thicken radiator fins.
2. Product
Input voltage: 5.0-30v
Output voltage: 0.5-30v
Output current: can work stably at 3A for a long time, and can reach 4A under enhanced heat dissipation
Output power: natural heat dissipation 35W, strengthen heat dissipation 50W
Voltage display resolution: 0.01V
Current display resolution: 0.001A
Conversion efficiency: about 88%
Soft start: yes (with high power and load module may fail when starting)
Protection mechanism:
Input anti-reverse connection;
Output anti-reverse irrigation;
Input undervoltage protection (4.8-30v adjustable, default 4.8v)
Output overvoltage protection (0.5-31v adjustable, default 31V)
Output overcurrent protection 0-4.1a (adjustable, default 4.1a)
Overpower protection (0-50w adjustable, default 50W)
Overtemperature protection (80-110℃ adjustable, default 110℃)
Timeout protection (0-100h adjustable, off by default)
Super capacity protection (0-60ah adjustable, off by default)
Operating frequency: 180KHZ
Dimensions: length * width * height 79mm*43mm*26mm
Weight: 92g (including package)
3. Key description
Note: after the product triggers the protection mechanism, the output will automatically turn off, the LCD will display the protection e, and press any key to exit the protection interface.
4. Interface description
5. Method of use
5.1. Switch display -- in the normal interface, press SW to switch the display below the display screen, and switch the display content between current A power W capacity Ah time h.Long press SW button to switch the uplink display on the display screen and switch the display content between input voltage IN output voltage OUT.
5.2. Set output voltage -- press U/I button in the normal interface to enter the interface of setting voltage constant current.It can be seen that a certain digit of the output voltage value is flashing. Rotate the ener left and right to adjust the major and minor.Short press the rotary ener to choose which bit of output voltage to set.After setting, press U/I button 2 times to return to the normal interface.Or automatically return to the normal interface after stopping operation for 10s.
5.3. Set constant current value (that is, the maximum current value allowed to output by the module) -- press U/I button in the normal interface to enter the setting voltage constant current interface.Then press U/I button and switch to setting constant current value. You can see a bit of the setting constant current value flashing. Rotate the rotary ener left and right to adjust the major and minor.Short press the rotary ener to choose which bit to set the constant current value.After setting, press U/I to exit the setting voltage constant current interface and return to the normal interface.Or automatically return to the normal interface after stopping operation for 10s.
5.4. Set the default on/off state of module power-on -- long press U/I in the normal interface to enter the parameter setting interface.You can see that it shows "OPEN OFF" or "OPEN ON". "OPEN OFF" means the output is turned OFF by default when power is ON, and "OPEN ON" means the output is turned ON by default when power is ON.Long press rotate ener to switch two states.After setting, long press U/I to return to the normal interface.
5.5. Setting of protection on state and threshold -- long press U/I to enter the parameter setting interface in the normal interface.Press SW until the protection you want appears.LUP -- undervoltage protection threshold;OUP -- overvoltage protection threshold;OCP -- overcurrent protection threshold;OPP -- over power protection threshold;OAP -- ultra-capacity protection threshold;OHP timeout protection threshold;OTP -- overtemperature protection threshold.Short press rotate ener to select which bit you want to set the protection parameter.Long press the rotary ener to set the protection on or off (only timeout protection and supercapacity protection can be set to turn on/off, and other protection are turned on by default.).Rotate the ener left and right to make the bigger and smaller.After setting, long press U/I to return to the normal interface.
5.6. Calibration voltage and current -- press U/I button to enter the parameter setting interface under normal interface.Press SW until a parameter interface with CAL appears.The calibration input voltage interface with the symbol CAL+IN+V;The calibration output voltage interface with the symbol CAL+OUT+V;The calibration output current interface with the symbol CAL+OUT+A.Rotate the ener left and right to adjust the size of .After the adjustment is completed, long press the rotary ener to confirm the adjustment is completed, and the parameter value is no longer flashing.Long press U/I to return to the normal interface.
Note: in order to ensure the accuracy of calibration, calibration voltage -- above 12V can only be started;Calibration current - start calibration only when the current is above 1A.
6. Packing form
7. Cautions
7.1. Short connection between input IN and output OUT of the module is forbidden, or the constant current function will fail.
7.2. Please ensure that the power moment of the power supply exceeds the required power of the output load!
7.3. If the module wants to output with full load, the input voltage should be above 8V. When the input voltage is 5V, the output power is about 15W.The maximum module current value is 4A, subject to the maximum output power, such as 17V, the current should not be greater than 2A.
7.4. When this module is used over 3A and 35W, please strengthen heat dissipation!!!
7.5. The module has input undervoltage protection function, which is about 4.8v by default (it can be set), and the output will be automatically disconnected after the value is lower than this value (note that the voltage at the module port is lower than the undervoltage protection threshold, and when the input current is relatively large, do not ignore the partial voltage on the input wire).
8. Service statement
8.1 all products are guaranteed for one year and returned without reason for seven days;For product quality problems within 30 days (except those caused by artificial damage or improper use), we guarantee to return or replace the products and bear the freight.For more than 30 days, the buyer will bear the back and forth freight, and we will repair the damage caused by the customer for free.
8.2 if the responsibility is not clear, we will make compensation after identifying the problem.Module overload short circuit and other improper use caused by the explosion of aircraft, chip burning will not make compensation.
8.3. Electronic module products require you to have a certain electronic foundation, and read the product description carefully before using;The product is not designed to be used for medical treatment, life saving and livelihood, and cannot be used in dangerous places such as coal mine and oil depot.The product profit is low, the user's operation ability and the use occasion varies greatly, if this shop product and your own valuable instrument equipment or digital products compatible use, cause any damage we do not guarantee, we only have the ability to compensate the module and freight.
8.4. Instructions for returning goods: if you refuse to receive the goods upon receipt of the goods, please attach a piece of paper indicating: 1.Purchase store name. 2. Cause of failure.3. Contact information.