This website uses cookies
This website uses cookies. For further information on how we use cookies you can read our Privacy and Cookie notice
This website uses cookies. For further information on how we use cookies you can read our Privacy and Cookie notice
In stock
Shipped from abroad
Free return within 15 days for all eligible items.Details
Yewulinjinanshangmaoyouxiangongsi
54%Seller Score
19 Followers
Shipping speed: Good
Quality Score: Very Poor
Customer Rating: Good
High cost performance programmable CNC adjustable step-down power supply module
(DIY desktop CNC small power supply, you can easily do it yourself)
1. Baby highlights:
1.1 LCD can display input/output voltage, output current/output power/output capacity/output time;
1.2. CNC adjustment, accurate and fast, can lower voltage, output voltage can be adjusted at will from 0-50.00v, limit current 0-12.00a can be adjusted at will;
1.3. the output end is poured backward without burning;
1.4. The module can be set to open/close by default;
1.5. Multiple software protection mechanisms are available, and the protection threshold is adjustable.When the working parameters of the module exceed the protection threshold, the output will be automatically closed.
1.6. Using synchronous rectification technology, the conversion efficiency is high: the efficiency is more than 90%.
1.7.Increase heat sink, install fan, strengthen heat diipation.
2. Product parameters
model:WZ5005L
display:LCD
Input voltage range:6-55.00V
Input voltage resolution:0.01V
Output voltage range:0-50.00V
Output voltage resolution:0.01V
Output current range:0-12.00A
Output current resolution:0.01A
Output power range:0-600.0W
Input voltage accuracy:±(1%+5)
Output voltage accuracy:±(0.3%+5)
Output current accuracy:±(0.5%+5)
Typical value of output ripple:150mVPeak value
Normal operating temperature range:-10℃~40℃
Capacitymeasurement range:0-999.9AH
Statistical error of capacity energy:
±2%
Statistical time range:0-100hour
Depreurization mode:differential preure>0.05%+1V
The weight of nude: 199g
Including packing:242g
Product size:panel79X43X42mm
main board:106x76x40mm
Soft start: Yes
Protection mechanism:
Input undervoltage protection (5.8-50v adjustable, default 5.8v)
Output overvoltage protection (0-51.00v adjustable, default 51V)
Output over-current protection (0-12.10a adjustable, default12.10a)
Timeout protection (0-100h adjustable, off by default)
Over capacity protection (0–999.9ah adjustable, off by default)
3. Key description
Note: after the product triggers the protection mechanism, the output will automatically turn off, the LCD will display the protection code, and pre any key to exit the protection interface.
4. Interface description
5. Method of use
5.1.Switch display parameters-- in the normal interface, pre SW to switch the display below the display screen, and switch the display content between current A power W capacity Ah time h.Long pre SW button to switch the uplink display on the display screen and switch the display content between input voltage IN output voltage OUT.
5.2.Set output voltage-- pre U/I button in the normal interface to enter the interface of setting voltage constant current.It can be seen that a certain digit of the output voltage value is flashing. Rotate the encoder left and right to adjust the major and minor.Short pre the rotary encoder to choose which bit of output voltage to set.After setting, pre U/I button 2 times to return to the normal interface.Or automatically return to the normal interface after stopping operation for 10s.
5.3.Set constant current value(that is, the maximum current value allowed to output by the module) -- pre U/I button in the normal interface to enter the setting voltage constant current interface.Then pre U/I button and switch to setting constant current value. You can see a bit of the setting constant current value flashing. Rotate the rotary encoder left and right to adjust the major and minor.Short pre the rotary encoder to choose which bit to set the constant current value.After setting, pre U/I to exit the setting voltage constant current interface and return to the normal interface.Or automatically return to the normal interface after stopping operation for 10s.
5.4.Set the default on/off state of module power-on-- long pre U/I in the normal interface to enter the parameter setting interface.You can see that it shows "OPEN OFF" or "OPEN ON". "OPEN OFF" means the output is turned OFF by default when power is ON, and "OPEN ON" means the output is turned ON by default when power is ON.Long pre rotate encoder to switch two states.After setting, long pre U/I to return to the normal interface.
5.5.Setting of protection parameters on state and threshold-- long pre U/I to enter the parameter setting interface in the normal interface.Pre SW until the protection you want appears.LUP -- undervoltage protectionthreshold;OUP -- overvoltage protection threshold;OCP -- overcurrent protection threshold;OAP -- ultra-capacity protection threshold;OHP timeout protection threshold.Short pre rotate encoder to select which bit you want to set the protection parameter.Long pre the rotary encoder to set the protection parameters on or off (only timeout protection and supercapacity protection can be set to turn on/off, and other protection parameters are turned on by default.).Rotate the encoder left and right to make the parameters bigger and smaller.After setting, long pre U/I to return to the normal interface.
5.6.Calibration voltage and current-- pre U/I button to enter the parameter setting interface under normal interface.Pre SW key for a short time until the interface with zero appears, with zero + out + a symbol. Pre and hold the rotary encoder to complete zero calibration. Short pre SW button until a parameter interface with CAL appears.The calibration input voltage interface with the symbol CAL+IN+V;The calibration output voltage interface with the symbol CAL+OUT+V;The calibration output current interface with the symbol CAL+OUT+A.Rotate the encoder left and right to adjust the size of parameters.After the adjustment is completed, long pre the rotary encoder to confirm the adjustment is completed, and the parameter value is no longer flashing.Long pre U/I to return to the normal interface.
Note: in order to ensure the accuracy of calibration, calibration voltage -- above 12V can only be started;Calibration current - start calibration only when the current is above 1A.
6. Packing form
7. Cautions
7.1.The module input positive in + and negative in - must not be reversed, and the module input in - must not be short circuited with the output out -, otherwise the module may be burnt out.
7.2. Please ensure that the power moment of the power supply exceeds the required power of the output load!
7.3.This module is a step-down module, the input voltage should be higher than the output voltage, and a certain margin should be reserved. For full load output, the input voltage should be 55v.
7.4. High power use of this module, serious heating, high temperature, be careful of scald! Please pay attention to ventilation and heat diipation when using high power for a long time!
7.5. The module has input undervoltage protection function. The default value is about 5.8v (can be set). When the value is lower than this value, the output will be automatically disconnected (note that the voltage at the module port is lower than the undervoltage protection threshold. When the input current is relatively large, do not ignore the partial voltage on the input wire).
This product has no ratings yet.
Subscribe to our newsletter
and be the first one to know about our amazing deals!