product_image_name-Generic-DC-DC Buck Boost Converter CCCV 0 5-30V 4A 5V 6V 12V PowerTech adjustable adjustable adjustable laboratory power supply-1product_image_name-Generic-DC-DC Buck Boost Converter CCCV 0 5-30V 4A 5V 6V 12V PowerTech adjustable adjustable adjustable laboratory power supply-2product_image_name-Generic-DC-DC Buck Boost Converter CCCV 0 5-30V 4A 5V 6V 12V PowerTech adjustable adjustable adjustable laboratory power supply-3product_image_name-Generic-DC-DC Buck Boost Converter CCCV 0 5-30V 4A 5V 6V 12V PowerTech adjustable adjustable adjustable laboratory power supply-4product_image_name-Generic-DC-DC Buck Boost Converter CCCV 0 5-30V 4A 5V 6V 12V PowerTech adjustable adjustable adjustable laboratory power supply-5product_image_name-Generic-DC-DC Buck Boost Converter CCCV 0 5-30V 4A 5V 6V 12V PowerTech adjustable adjustable adjustable laboratory power supply-6

Share this product

Shipped from abroad

DC-DC Buck Boost Converter CCCV 0 5-30V 4A 5V 6V 12V PowerTech adjustable adjustable adjustable laboratory power supply

GH₵ 454.41
GH₵ 856.8047%

In stock

Order above GHC 150 on Jumia Express items & get free delivery | regular delivery from GH₵ 48.47 to Tema
Variation available

Promotions

Delivery & Returns

Shipped from abroad 

Choose your location

Pickup Station

Delivery Fees GH₵ 48.47
Ready for pickup between 10 October & 15 October when you order within next 11hrs 42mins

Door Delivery

Delivery Fees GH₵ 60.37
Ready for delivery between 10 October & 15 October when you order within next 11hrs 42mins

Return Policy

Free return within 15 days for all eligible items.Details

Seller Information

Auto parts, lighting accessories, and tools

60%Seller Score

Be the first to follow

Follow

Seller Performance

This seller does not have enough history for us to evaluate his performance yet

Product details


DC-DC Buck Boost Converter CCCV 0 5-30V 4A 5V 6V 12V PowerTech adjustable adjustable adjustable laboratory power supply
  • I am an international seller
Our shop sells the most popular 3C consumer electronics products,such as mobile phone accessories,computer accessories,game peripherals,smart wearables,and follow the most popular fashion trends. If you like our products,please follow us,become our follower and fan.We will provide you with the most popular products to satisfy your fashion shopping experience.Personnalisé : OuiUsage : SVCNuméro de Modèle : ZK-4KXType actuel : DcPhase : MONOPHASÉNom de marque : Stlxy : CN Certification : NONE
Conversion efficiency: about 88%Soft start: yes (with high power and load module may fail when starting)Protection mechanism:Input anti-reverse connection;Output anti-reverse irrigation;Input undervoltage protection (4.8-30v adjustable, default 4.8v)Output overvoltage protection (0.5-31v adjustable, default 31V)Output overcurrent protection 0-4.1a (adjustable, default 4.1a)Overpower protection (0-50w adjustable, default 50W)Overtemperature protection (80-110℃ adjustable, default 110℃)Timeout protection (0-100h adjustable, off by default)Super capacity protection (0-60ah adjustable, off by default)Operating frequency: 180KHZDimensions: length * width * height 79mm*43mm*26mmWeight: 92g (including package) Method of use5.1. Switch display -- in the normal interface, press SW to switch the display below the display screen, and switch the display content between current A power W capacity Ah time h.Long press SW button to switch the uplink display on the display screen and switch the display content between input voltage IN output voltage OUT.5.2. Set output voltage -- press U/I button in the normal interface to enter the interface of setting voltage constant current.It can be seen that a certain digit of the output voltage value is flashing. Rotate the ener left and right to adjust the major and minor.Short press the rotary ener to choose which bit of output voltage to set.After setting, press U/I button 2 times to return to the normal interface.Or automatically return to the normal interface after stopping operation for 10s.5.3. Set constant current value (that is, the maximum current value allowed to output by the module) -- press U/I button in the normal interface to enter the setting voltage constant current interface.Then press U/I button and switch to setting constant current value. You can see a bit of the setting constant current value flashing. Rotate the rotary ener left and right to adjust the major and minor.Short press the rotary ener to choose which bit to set the constant current value.After setting, press U/I to exit the setting voltage constant current interface and return to the normal interface.Or automatically return to the normal interface after stopping operation for 10s.5.4. Set the default on/off state of module power-on -- long press U/I in the normal interface to enter the parameter setting interface.You can see that it shows "OPEN OFF" or "OPEN ON". "OPEN OFF" means the output is turned OFF by default when power is ON, and "OPEN ON" means the output is turned ON by default when power is ON.Long press rotate ener to switch two states.After setting, long press U/I to return to the normal interface.5.5. Setting of protection on state and threshold -- long press U/I to enter the parameter setting interface in the normal interface.Press SW until the protection you want appears.LUP -- undervoltage protection threshold;OUP -- overvoltage protection threshold;OCP -- overcurrent protection threshold;OPP -- over power protection threshold;OAP -- ultra-capacity protection threshold;OHP timeout protection threshold;OTP -- overtemperature protection threshold.Short press rotate ener to select which bit you want to set the protection parameter.Long press the rotary ener to set the protection on or off (only timeout protection and supercapacity protection can be set to turn on/off, and other protection are turned on by default.).Rotate the ener left and right to make the bigger and smaller.After setting, long press U/I to return to the normal interface.5.6. Calibration voltage and current -- press U/I button to enter the parameter setting interface under normal interface.Press SW until a parameter interface with CAL appears.The calibration input voltage interface with the symbol CAL+IN+V;The calibration output voltage interface with the symbol CAL+OUT+V;The calibration output current interface with the symbol CAL+OUT+A.Rotate the ener left and right to adjust the size of .After the adjustment is completed, long press the rotary ener to confirm the adjustment is completed, and the parameter value is no longer flashing.Long press U/I to return to the normal interface. Note: in order to ensure the accuracy of calibration, calibration voltage -- above 12V can only be started;Calibration current - start calibration only when the current is above 1A.Cautions7.1. Short connection between input IN and output OUT of the module is forbidden, or the constant current function will fail.7.2. Please ensure that the power moment of the power supply exceeds the required power of the output load!7.3. If the module wants to output with full load, the input voltage should be above 8V. When the input voltage is 5V, the output power is about 15W.The maximum module current value is 4A, subject to the maximum output power, such as 17V, the current should not be greater than 2A.7.4. When this module is used over 3A and 35W, please strengthen heat dissipation!!!7.5. The module has input undervoltage protection function, which is about 4.8v by default (it can be set), and the output will be automatically disconnected after the value is lower than this value (note that the voltage at the module port is lower than the undervoltage protection threshold, and when the input current is relatively large, do not ignore the partial voltage on the input wire).
image


image


image


image

Specifications

Key Features

Personnalisé : OuiUsage : SVCNuméro de Modèle : ZK-4KXType actuel : DcPhase : MONOPHASÉNom de marque : Stlxy : CN Certification : NONE
Conversion efficiency: about 88%Soft start: yes (with high power and load module may fail when starting)Protection mechanism:Input anti-reverse connection;Output anti-reverse irrigation;Input undervoltage protection (4.8-30v adjustable, default 4.8v)Output overvoltage protection (0.5-31v adjustable, default 31V)Output overcurrent protection 0-4.1a (adjustable, default 4.1a)Overpower protection (0-50w adjustable, default 50W)Overtemperature protection (80-110℃ adjustable, default 110℃)Timeout protection (0-100h adjustable, off by default)Super capacity protection (0-60ah adjustable, off by default)Operating frequency: 180KHZDimensions: length * width * height 79mm*43mm*26mmWeight: 92g (including package) Method of use5.1. Switch display -- in the normal interface, press SW to switch the display below the display screen, and switch the display content between current A power W capacity Ah time h.Long press SW button to switch the uplink display on the display screen and switch the display content between input voltage IN output voltage OUT.5.2. Set output voltage -- press U/I button in the normal interface to enter the interface of setting voltage constant current.It can be seen that a certain digit of the output voltage value is flashing. Rotate the ener left and right to adjust the major and minor.Short press the rotary ener to choose which bit of output voltage to set.After setting, press U/I button 2 times to return to the normal interface.Or automatically return to the normal interface after stopping operation for 10s.5.3. Set constant current value (that is, the maximum current value allowed to output by the module) -- press U/I button in the normal interface to enter the setting voltage constant current interface.Then press U/I button and switch to setting constant current value. You can see a bit of the setting constant current value flashing. Rotate the rotary ener left and right to adjust the major and minor.Short press the rotary ener to choose which bit to set the constant current value.After setting, press U/I to exit the setting voltage constant current interface and return to the normal interface.Or automatically return to the normal interface after stopping operation for 10s.5.4. Set the default on/off state of module power-on -- long press U/I in the normal interface to enter the parameter setting interface.You can see that it shows "OPEN OFF" or "OPEN ON". "OPEN OFF" means the output is turned OFF by default when power is ON, and "OPEN ON" means the output is turned ON by default when power is ON.Long press rotate ener to switch two states.After setting, long press U/I to return to the normal interface.5.5. Setting of protection on state and threshold -- long press U/I to enter the parameter setting interface in the normal interface.Press SW until the protection you want appears.LUP -- undervoltage protection threshold;OUP -- overvoltage protection threshold;OCP -- overcurrent protection threshold;OPP -- over power protection threshold;OAP -- ultra-capacity protection threshold;OHP timeout protection threshold;OTP -- overtemperature protection threshold.Short press rotate ener to select which bit you want to set the protection parameter.Long press the rotary ener to set the protection on or off (only timeout protection and supercapacity protection can be set to turn on/off, and other protection are turned on by default.).Rotate the ener left and right to make the bigger and smaller.After setting, long press U/I to return to the normal interface.5.6. Calibration voltage and current -- press U/I button to enter the parameter setting interface under normal interface.Press SW until a parameter interface with CAL appears.The calibration input voltage interface with the symbol CAL+IN+V;The calibration output voltage interface with the symbol CAL+OUT+V;The calibration output current interface with the symbol CAL+OUT+A.Rotate the ener left and right to adjust the size of .After the adjustment is completed, long press the rotary ener to confirm the adjustment is completed, and the parameter value is no longer flashing.Long press U/I to return to the normal interface. Note: in order to ensure the accuracy of calibration, calibration voltage -- above 12V can only be started;Calibration current - start calibration only when the current is above 1A.Cautions7.1. Short connection between input IN and output OUT of the module is forbidden, or the constant current function will fail.7.2. Please ensure that the power moment of the power supply exceeds the required power of the output load!7.3. If the module wants to output with full load, the input voltage should be above 8V. When the input voltage is 5V, the output power is about 15W.The maximum module current value is 4A, subject to the maximum output power, such as 17V, the current should not be greater than 2A.7.4. When this module is used over 3A and 35W, please strengthen heat dissipation!!!7.5. The module has input undervoltage protection function, which is about 4.8v by default (it can be set), and the output will be automatically disconnected after the value is lower than this value (note that the voltage at the module port is lower than the undervoltage protection threshold, and when the input current is relatively large, do not ignore the partial voltage on the input wire).

What’s in the box

1x packages

Specifications

  • SKU: GE779VP4XM1F5NAFAMZ
  • Model: SM-WDQ-4-15-51
  • Production Country: China
  • Size (L x W x H cm): 20x10x20
  • Weight (kg): 0.3
  • Color: multicolour
  • Main Material: other