This website uses cookies
This website uses cookies. For further information on how we use cookies you can read our Privacy and Cookie notice
This website uses cookies. For further information on how we use cookies you can read our Privacy and Cookie notice
In stock
Shipped from abroad
Free return within 15 days for all eligible items.Details
Youngeer
80%Seller Score
20 Followers
Shipping speed: Average
Quality Score: Excellent
5V 1/8NPT Stainle Steel Fuel Preure Transducer Sender For Oil Air Water 5/15/30/60/100/150/200/300/500/1000/1600 Psi
Specification: Product Name: Oil Fuel PreureTransducer Material: Stainle Steel & Rubber Color: Sier & Black Voltage: DC 5V Length: 53mm Thread: 1/8"-27 NPT / 1/8" NPT Preure: 5psi, 15psi, 30psi,60psi, 100psi, 150psi,200psi,300psi,500psi,1000psi,1600psi
15 psi Input: 0-15 psi Output: 0.5-4.5V linear voltage output. 0 psi outputs 0.5V, 7.5 psi outputs 2.5V, 15 psi outputs 4.5V. Accuracy: +/-0.5%FS; Thread: 1/8” NPT; Wiring Connector: Packard plug-in unit is included; Wiring: Red: +5V; Black: ground; Green: signal output; Overload Capacity: 2-4 times; Working Temperature: -40—+120C; Compensation Temperature: -20—+80C; Protection Cla: 67; Preure Medium: The gas and liquid which is compatible with 316L stainle steel; Load Resistance: ≤ (supply power-6.5V/0.02A)Ω; Long-term stability: Le than 0.1%FS/year; Temperature Effect on Zero: Typical:0.02%FS/C; Maximum:0.05%FS/C; Temperature Effect on Sensitivity: Typical:0.02%FS/C; Maximum:0.05%FS/C; Shock Resistance: 1000g; Anti-Shock: ≤+/-0.01%FS(X,Y,Z axes, 200Hz/g); Response Time: ≤1ms; Insulation Resistance: >100mΩ 500VDC; Explosion-proof Cla: ExiaTTCT6; Electromagnetism Compatibility: EN50051-1. 30 psi Input: 0-30 psi. Output: 0.5V – 4.5V linear voltage output. 0 psi outputs 0.5V, 15psi outputs 2.5V, 30 psi outputs 4.5V. Accuracy: within 2% of reading (full scale). Thread: 1/8”-27 NPT. Wiring connector: water sealed quick disconnect. Mating connector is included. Wiring: Red for +5V. Black for ground. Blue for signal output.
100 psi Input: 0-100 psi. Output: 0.5V – 4.5V linear voltage output. 0 psi outputs 0.5V, 50 psi outputs 2.5V, 100 psi outputs 4.5V. Accuracy: within 2% of reading (full scale). Thread: 1/8”-27 NPT. Wiring connector: water sealed quick disconnect. Mating connector and wire harne (pigtail) is included. Wiring: Red for +5V. Black for ground. Blue for signal output.
200 psi Preure Range: 0-200 psi Output: 0.5V – 4.5V linear voltage output. 0 psi outputs 0.5V, 100 psi outputs 2.5V, 200 psi outputs 4.5V Working Temperature: -40—+125C;. Accuracy: ±1%FS; Thread: 1/8”-27 NPT. Overload Capacity: 2 times; Preure Medium: The gas and liquid which is compatible with 316L stainle steel; Load Resistance: ≤(supply power-6.5V/0.02A)Ω; Long-term stability: ± 0.2%FS/year; Temperature Effect on Zero: Typical: ±0.02%FS/C; Maximum: ±0.05%FS/C; Temperature Effect on Sensitivity: Typical: ±0.02%FS/C; Maximum: ±0.05%FS/C; Shock Resistance: 100g; Anti-Shock: ≤±0.01%FS(X,Y,Z axes, 200Hz/g); Response Time: ≤1ms; Insulation Resistance: >100mΩ 500VDC; Explosion-proof Cla: ExiaTTCT6; Electromagnetism Compatibility: EN50081-1; EN50082-2; IEC6 1000-4-3 Wiring: Red for IN+. Black for GND. Green for OUT. 300psi Input: 0-300 psi(Gauge Preure); Output: 0.5-4.5V linear voltage output. 0 psi outputs 0.5V, 150 psi outputs 2.5V, 300 psi outputs 4.5V. Accuracy: +/-0.5%FS; Thread: 1/8” NPT; Wiring Connector: Packard plug-in unit is included; Wiring: Red: +5V; Black: ground; Green: signal output; Overload Capacity: 2-4 times; Working Temperature: -40—+120C; Compensation Temperature: -20—+80C; Protection Cla: 67; Preure Medium: The gas and liquid which is compatible with 316L stainle steel; Load Resistance: ≤ (supply power-6.5V/0.02A)Ω; Long-term stability: Le than 0.1%FS/year; Temperature Effect on Zero: Typical:0.02%FS/C; Maximum:0.05%FS/C; Temperature Effect on Sensitivity: Typical:0.02%FS/C; Maximum:0.05%FS/C; Shock Resistance: 1000g; Anti-Shock: ≤+/-0.01%FS(X,Y,Z axes, 200Hz/g); Response Time: ≤1ms; Insulation Resistance: >100mΩ 500VDC; Explosion-proof Cla: ExiaTTCT6; Electromagnetism Compatibility: EN50051-1. 500 psi Input: 0-500 psi(Gauge Preure); Output: 0.5-4.5V linear voltage output. 0 psi outputs 0.5V, 250 psi outputs 2.5V, 500 psi outputs 4.5V. 1000 psi Input: 0-1000 psi. Output: 0.5V – 4.5V linear voltage out
1600psi Input: 0-1600 psi(Gauge Preure); Output: 0.5-4.5V linear voltage output. 0 psi outputs 0.5V, 80 Fitment: For oil, fuel, , gas, water, air preure Can be used in oil tank, gas tank, tank etc.
Features: -It's an advance preure sender than traditional mechanical preure sender; -CMC for Load Cell Sensor; -CMC for Preure and Pull Preure Sensor.
Package Includes: 1 x Preure Transducer (With Cable)
/ About service / On- Time Delivery Full if product isn't received in guaranteed delivery time Longer Protection 15 day more protection after order completion Returns Extra Return any product,only those in perfect condition Guaranteed Quality Guaranteed Quality or Full
If you have any probl with our it or services, please feel free to contact us first before you leave negative feedback. We will do our best to soe any problem and provide you with the best customer services.
About shping
This product has no ratings yet.
Subscribe to our newsletter
and be the first one to know about our amazing deals!