HomeIndustrial & ScientificIndustrial ElectricalSemiconductor ProductsInterfacesCommunication Integrated CircuitsDC 660V 30A LCD Leadacid Solar Battery Charge Controller Protection Board Charger Time Switch 12V 24V 36V 48V Battery Capacity
product_image_name-Fashion-DC 660V 30A LCD Leadacid Solar Battery Charge Controller Protection Board Charger Time Switch 12V 24V 36V 48V Battery Capacity-1

Share this product

Shipped from abroad

Fashion DC 660V 30A LCD Leadacid Solar Battery Charge Controller Protection Board Charger Time Switch 12V 24V 36V 48V Battery Capacity

GH₵ 342.08
GH₵ 590.5242%

In stock

Order above GHC 150 on Jumia Express items & get free delivery | regular delivery from GH₵ 40.61 to Tema
0 out of 5
(No ratings available)
Variation available

2offers starting fromGH₵ 342.08

See More Offers

Promotions

Delivery & Returns

Shipped from abroad 

Choose your location

Pickup Station

Delivery Fees GH₵ 40.61
Ready for pickup between 18 November & 21 November when you order within next 2hrs 1mins

Door Delivery

Delivery Fees GH₵ 52.51
Ready for delivery between 18 November & 21 November when you order within next 2hrs 1mins

Return Policy

Free return within 15 days for all eligible items.Details

Seller Information

Sugo Fashion

54%Seller Score

9 Followers

Follow

Seller Performance

Shipping speed: Excellent

Quality Score: Very Poor

Customer Rating: Average

Compare Offers

GH₵ 586.40

Sold by: waruanrong | Seller Score: 60%

Product details

1. Support Lead-acid battery and Acting Battery,voltage range: DC 6V~60V;

2. Can display voltage,percent of battery,charging time at the same time through LCD;

3.  The function is very powerful,realizes the automatic charge control,

the control charge time, also may set up and uploads the corresponding parameter through the serial port;

Function description 1. Automatic Charge control function:

By setting the volt-HI:‘UP’ volt-LI:‘dn’;When the battery voltage is below the volt-LI:’dn’,the relay leads,the charger begins to charge the battery;when the battery voltage is up to volt-HI:’UP’,the relay is diconnected and the automatic charge is completed once;

2. Charge Time Control Function:

How to turn on the time control function?

Ar entering the parameter set, set the parameter op is non-zero, then turn on the time control function, op default parameter is:--:--h, the default does not turn on time control function;

Ar the opening Time control function (OP is non-zero), when the battery voltage is the lower volt-LI’dn’, the charger began to charge the battery, the system began to clock; During the timing, the battery voltage ≥ volt-HI’UP’, relay disconnect; If the OP time is up, the battery voltage is still the lower volt-LI’dn’, the relay keeps the conduction, automatically closes the charge time control function, and flashes the H:ER to remind the user, the time parameter setting is unreasonable; Pre any key to stop flashing;

Note: Time format: 00:59 (00 for hours, 59 for minutes) The maximum time is 99:59, which is 100 hours.

3. Serial data upload and parameter setting function:

The system supports UART data upload and parameter setting

UART:115200,8,1

Cmd

Function

on

Relays enable to open

off

Relays disable to open

start

Start data upload

stop

Stop data upload

read

Read the param setting

dw10.0

Set volt-LI:’dn’

up20.0

Set volt-HI:’UP’

xx:xx

Set the charge time OP

00:00 stop charge time

Data Upload meage Format:

Battery voltage + battery percent + charge time + charge status 12.0V,020%,00:10,OP

Parameter Setting

a) Pre and hold the SET key to enter the setting interface;

b) Switch the you want to set by short pre SET;

c) Ar the selection of , can be set by the UP/DOWN key to support the short pre, long pre (fast increase or decrease); To set other , repeat step b, c);

d) Ar all are set, long pre set key to exit and save;

The Key Function Description:

In the Run interface (main interface):

Short pre SET on to display the current set of ; Short pre UP on, tole display charge percentage and charging time;

Short Pre DOWN on, select Turn on/off relay enabling, if the relay can be closed, will show ' off ' as a reminder;

Long pre UP on, switch low power state

on:No operation in 10 minutes turn off backlight

OFF: Backlight is always bright

Long pre SET on,enter the parameter settings.

Calculation of voltage percentage:

voltage percentage = battery voltage/(volt-HI – volt-LI)

Additional Features

a) Charging time recording function: not open charging time control, the product will record a full time, when the entry time display interface, flashing display charging time, and then exit time display interface or charge to open (relay conduction) when empty;

b) Automatic parameter detection: When the are set, exit, if volt-LI dn≥ volt-HI UP, the system will flash display "ERR" as a reminder;

c) Battery Acce detection: This product attached to the battery, if not connected to the battery, the system will be shown in the downlink "NbE" as a reminder

Analysis of common fai

Q: How much is suitable for V level use? How much v voltage does this module fit?

A: This section is suitable for the minimum 6V, the highest 60V voltage range, the maximum expenditure level 48V, because 48V battery full of electricity in 60V, and then a high fever, if your battery is higher than 48V, please select other section.

Q: The power of the subsequent electrical appliances snapped! LED flashing?

A: This is because your charging current is too large or the battery capacity is too small to cause a power to immediately reach the voltage limit, relay disconnect, disconnect, the voltage and quickly down to the lower voltage, and began to recharge, cycle, at this time you want to reduce the charging current only line, Usually the charging current is the battery capacity of the very 1 to 1.5, such as 20AH battery charging current generally around 2-3a! Note that a large current charge will cause the battery fever accelerated aging, drum kits and even explosions!

Q: What control mode? Can I cycle the charge automatically? Can I use the side charge? Can I limit the flow?

A: This is voltage control, For example, set the voltage limit of 12.0V, voltage up to 14.5V, voltage charge to 14.5V this value on the power off, voltage down to the 12.0V relay closed and start charging, can be filled with side, voltage control mode only to turn off and open, can not limit the flow, charging current completely depends on your charger!

Q: Input 12V can or not charge 24V battery, or enter 48V can give 12V battery charge?

A:This is a simple voltage controller, only play the role of switch, can not swing to the battery charge, so you want to give what battery charge to be ready what kind of charger! It's neceary!

image image image image image image image

About shipping
Shipping and Packaging All it will be double checked and well packed before sending.It will be dispatched within 2 business days ar buyers pay for the order. It usually takes about 14 to 18 working days for delivering the package to the destination(for remote areas,it may take a little longer). 

Special Announcement:
Please fill in the correct and detailed consignee, address and phone number in the order. For fast and correct delivery.If you do not receive order within 30 working days,please feel free to contact Customer Service before leaving Negative and Neutral Feedback, we will do our best to help you resolve the problem.TaxNo, you will only pay what is quoted as total cost at checkout, no more. You are not expected to pay any additional duties ores. If you are asked by Customs or our logistic partner to pay duties, please contact our Customer Service .

Your 100% satisfaction is very ant to us
If the product is not on good condition, You can return this product within 14 working days, please contact customer service center before returning.FeedbackYour satisfaction is our first priorityIf you receive the order and it is in good condition,we would be grateful if you would leave us 5 star Positive Feedback for the transaction.

Specifications

Key Features

  • Origin:Mainland China
  • Condition:New
  • Type:Voltage Regulator
  • Model Number:30A 6-60V Lead-Acid Lithium Battery Charger Control Module
  • is_customized:Yes
  • Application:Computer

What’s in the box

1X DC 6-60V 30A LCD Lead-acid Solar Battery Charge Controller Protection Board Charger Time Switch 12V 24V 36V 48V Battery Capacity

Specifications

  • SKU: FA114IP2JSOQYNAFAMZ
  • Product Line: Fashion
  • Model: BONjicehngdianlu4870
  • Production Country: China
  • Size (L x W x H cm): 10x8x6
  • Weight (kg): 0.2
  • Color: XY-L30A
  • Main Material: PVC

Verified Customer Feedback

This product has no ratings yet.

Fashion DC 660V 30A LCD Leadacid Solar Battery Charge Controller Protection Board Charger Time Switch 12V 24V 36V 48V Battery Capacity

Fashion DC 660V 30A LCD Leadacid Solar Battery Charge Controller Protection Board Charger Time Switch 12V 24V 36V 48V Battery Capacity

GH₵ 342.08
GH₵ 590.5242%
Questions about this product?

Recently Viewed

See All