HomeElectronicsWearable TechnologyAccessoriesSmart Watch AccessoriesSmart Watch Bands24V Explosion-proof Type Heating Cable 8mm Width Heating Wire With Metal
product_image_name-Generic-24V Explosion-proof Type Heating Cable 8mm Width Heating Wire With Metal-1

Share this product

Shipped from abroad

24V Explosion-proof Type Heating Cable 8mm Width Heating Wire With Metal

GH₵ 472.16
GH₵ 687.2331%

In stock

Order above GHC 150 on Jumia Express items & get free delivery | regular delivery from GH₵ 42.57 to Tema
0 out of 5
(No ratings available)
Variation available

5offers starting fromGH₵ 472.16

See More Offers

Promotions

Delivery & Returns

Shipped from abroad 

Choose your location

Pickup Station

Delivery Fees GH₵ 42.57
Ready for pickup between 17 January and 22 January if you place your order within the next 3hrs 31mins

Door Delivery

Delivery Fees GH₵ 56.85
Ready for delivery between 17 January and 22 January if you place your order within the next 3hrs 31mins

Return Policy

Free return within 15 days for all eligible items.Details

Seller Information

Puhanglin

60%Seller Score

Be the first to follow

Follow

Seller Performance

Quality Score: Excellent

Compare Offers

See all offers
GH₵ 536.84

Sold by: protein | Seller Score: 60%

Product details

Specifications:

Max. working temperature: 60C degree
Max. exposure temperature: 70C degree
Max. working length: 20M
Min. installation temperature: -40C degree
Voltage: 24V (Note:for 24V, do not beyond 20meters, redundant length will not heat up.)
Min. bend radius: @20C:25.4mm @-30C:35.0m

Cable Structure:
1. Copper-core wire: 7×0.42
2. Conductive heating elemen
3. HD polyolefin outer jacket
4. Metal braid explosion proof

Installation:

first unwind the heating cable. The cable must never be connected to the power line when it is wound up.
if the cable is too inflexible because of low temperatures, unwind it and put it for some minutes into the plug.
afterwards you can pass the cable.
the area around the pipe where you want to connect it with the cable must be accessibly and non-attached.
the heating cable can not be passed behind walls
put the thermostat (if need) with the round black contact area tightly on the coolest point of the pipe and fix it with insulating tape.
finally put the whole cable on the pipe and fasten it every 30~60cm with insulating tape.
attention: the cable must be fastening straight on the pipe
now you can check if your cable works.
afterwards insulate the water pipe and the heating cable with mineral rock wool or foam. Attention: never use more than 13mm of this material to insulate.
in general the heating cable must be protected against mechanical damage or biting.
the heating cable can not be put into liquids.
finally plug the cable into a 24V main plug

NOTE
DO NOT connect the two conductors together!image


image


image


image


image


image


image


image


image


image


image


image


image


image


image

Specifications

Key Features

Specifications:

Max. working temperature: 60C degree
Max. exposure temperature: 70C degree
Max. working length: 20M
Min. installation temperature: -40C degree
Voltage: 24V (Note:for 24V, do not beyond 20meters, redundant length will not heat up.)
Min. bend radius: @20C:25.4mm @-30C:35.0m

Cable Structure:
1. Copper-core wire: 7×0.42
2. Conductive heating elemen
3. HD polyolefin outer jacket
4. Metal braid explosion proof

Installation:

first unwind the heating cable. The cable must never be connected to the power line when it is wound up.
if the cable is too inflexible because of low temperatures, unwind it and put it for some minutes into the plug.
afterwards you can pass the cable.
the area around the pipe where you want to connect it with the cable must be accessibly and non-attached.
the heating cable can not be passed behind walls
put the thermostat (if need) with the round black contact area tightly on the coolest point of the pipe and fix it with insulating tape.
finally put the whole cable on the pipe and fasten it every 30~60cm with insulating tape.
attention: the cable must be fastening straight on the pipe
now you can check if your cable works.
afterwards insulate the water pipe and the heating cable with mineral rock wool or foam. Attention: never use more than 13mm of this material to insulate.
in general the heating cable must be protected against mechanical damage or biting.
the heating cable can not be put into liquids.
finally plug the cable into a 24V main plug

NOTE
DO NOT connect the two conductors together!

Specifications

  • SKU: GE779EA4JOX38NAFAMZ
  • Model: avoid chenicals
  • Production Country: China
  • Size (L x W x H cm): 12 x 13 x 14 cm
  • Weight (kg): 1
  • Color: Matches the image

Verified Customer Feedback

This product has no ratings yet.

24V Explosion-proof Type Heating Cable 8mm Width Heating Wire With Metal

24V Explosion-proof Type Heating Cable 8mm Width Heating Wire With Metal

GH₵ 472.16
GH₵ 687.2331%
Questions about this product?

Recently Viewed

See All